Листовка для I.R.I.S. LT800P

Скачать
Страница из 2
IRiS • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
02/26/2008 5:16:47 PM
Specifications and Dimensions subject to change without notice.
ADI060676
.
P406TAT MH4BT E4DLSR
D
FC
L
W
4'
43
3.4'
4.1'
5'
27
4.3'
5.2'
6'
19
5.1'
6.2'
7'
14
6.0'
7.2'
8'
11
6.9'
8.3'
Zone
Lumens
Lamp
Luminaire
 0- 30 
448
26.8
55.3
 0- 40 
637
38.1
78.6
 0- 60 
782
46.8
96.5
 0- 90 
810
48.5
100
 90-180 
0
0
0
 0-180  810
48.5
100
Spacing Criterion = .8, 1
Efficiency = 48.5%
Test No. P11009
Platform = P4
Element = E4DLSRH
Lumens = 1670
Lamp = 100BT15/HAL/W-
120V
100W
BT15
Downlight
45°
30°
15°
60°
75°
90°
250
500
750
90º
Ceiling 
Wall % 
RCR
70 50 30 10
70 50 30 10 
50 30 10
50 30 10
50 30 10
0
Zonal cavity method -- floor reflectance = 20%
0
58 58 58 58 
56 56 56 56 
54 54 54 
52 52 52 
50 50 50 
49
1
55 53 52 50 
53 52 51 50 
50 49 48 
48 47 47 
46 46 45 
44
2
51 49 46 44 
50 48 46 44 
46 44 43 
45 43 42 
43 42 41 
40
3
48 45 42 40 
47 44 41 39 
43 40 39 
41 40 38 
40 39 37 
37
4
45 41 38 36 
44 40 38 35 
39 37 35 
38 36 35 
37 36 34 
33
5
43 38 35 32 
42 37 34 32 
37 34 32 
36 33 32 
35 33 31 
30
6
40 35 32 29 
39 35 32 29 
34 31 29 
33 31 29 
33 30 29 
28
7
38 33 29 27 
37 32 29 27 
32 29 27 
31 29 27 
30 28 26 
26
8
36 30 27 25 
35 30 27 25 
30 27 25 
29 27 25 
29 26 25 
24
9
34 28 25 23 
33 28 25 23 
28 25 23 
27 25 23 
27 25 23 
22
10
32 27 24 21 
31 27 23 21 
26 23 21 
26 23 21 
25 23 21 
21
Photometric Results
Candlepower Distribution
Coefficients of Utilization
Cone of Light
Zonal Lumens Summary
Vertical 
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
1
8
20
40
73
198
396
574
680
685
Candelas
D
FC
L
W
4'
26
3.3'
3.0'
5'
17
4.2'
4.9'
6'
12
5.0'
5.8'
7'
8
5.8'
6.8'
8'
6
6.7'
7.8'
Zone
Lumens
Lamp
Luminaire
 0- 30 
262
25.9
55.2
 0- 40 
371
36.7
78.3
 0- 60 
457
45.3
96.5
 0- 90 
474
46.9
100
 90-180 
0
0
0
 0-180  474
46.9
100
Spacing Criterion = .8, 1
Efficiency = 46.9%
Test No. P11006
Platform = P4
Element = E4DLSRH
Lumens = 1010
Lamp = 75BT15/HAL/W-
120V
75W
BT15
Ceiling 
Wall % 
RCR
70 50 30 10
70 50 30 10 
50 30 10
50 30 10
50 30 10
0
Zonal cavity method -- floor reflectance = 20%
0
56 56 56 56 
54 54 54 54 
52 52 52 
50 50 50 
48 48 48 
47
1
53 51 50 49 
51 50 49 48 
48 47 46 
46 46 45 
45 44 44 
43
2
50 47 45 43 
48 46 44 42 
44 43 41 
43 42 40 
42 41 40 
39
3
47 43 40 38 
46 42 40 38 
41 39 37 
40 38 37 
39 37 36 
35
4
44 40 37 34 
43 39 36 34 
38 36 34 
37 35 33 
36 34 33 
32
5
41 37 33 31 
40 36 33 31 
35 33 31 
34 32 30 
34 32 30 
29
6
39 34 31 28 
38 34 31 28 
33 30 28 
32 30 28 
31 29 28 
27
7
36 32 28 26 
36 31 28 26 
31 28 26 
30 28 26 
29 27 26 
25
8
34 29 26 24 
34 29 26 24 
29 26 24 
28 26 24 
28 25 24 
23
9
33 28 24 22 
32 27 24 22 
27 24 22 
26 24 22 
26 24 22 
21
10
31 26 23 21 
30 26 23 21 
25 23 21 
25 22 21 
24 22 21 
20
Photometric Results
Coefficients of Utilization
Cone of Light
Zonal Lumens Summary
Downlight
45°
30°
15°
60°
75°
90°
140
280
420
90º
Candlepower Distribution
Vertical 
Angle
CD
90
85
75
65
55
45
35
25
15
5
0
0
1
5
12
24
48
127
235
341
411
414
Candelas