Installation 
(continued)
3
4) Connect T-Valve and Hoses
3) Install Mounting Plate (continued)
c)  Adjust mounting plate so length (L) between the front of the toilet 
bowl and the back of the mounting plate is as follows:
Round (EU44959):  
L=18¼" (465 mm)
Elongated (EV77959):  
L=20½"(495 mm)
d)  Tighten Mounting Bolts with screwdriver until the mounting plate is 
securely fastened to the toilet.  
NOTE: If your water supply line is rigid pipe, 
you may need to replace it before installing 
the Refresh Personal Hygiene System™.
a)  Install the T-Valve between the water supply line 
and the toilet tank.
b)  Place the Refresh on or beside the toilet and 
connect the Bidet Hose to the Refresh.
IMPORTANT: Use wrench to tighten all 
connections before continuing.  Failure to 
do so could result in flooding, leaking, or 
damage to the Refresh Personal Hygiene 
System™.  Do not overtighten!
5) Attach the Refresh
a)  Slide the Refresh onto the mounting plate.  
You will hear a “click” indicating the seat has 
been properly attached. 
 
Confirm that the seat switch is in full        
contact with the toilet bowl rim.
To Release the Refresh: 
Unplug the power plug and turn the water 
supply valve OFF.  
Push the button located on the right corner 
of the seat and gently pull.  
6) Turn ON Water & Connect Power
CAUTION: Use only a grounded 
15 Amp GFCI outlet!
a)  Turn the water supply valve ON slowly.  
Ensure the connections are not leaking 
before continuing.
IMPORTANT! Make sure work area is dry 
and hands are dry before continuing.
b)  Insert power plug into a grounded 15 Amp 
GFCI outlet.  The blue power LED on the 
Refresh Display Panel will illuminate.
IMPORTANT! Make sure the power plug is 
removed and the water supply is shut-off 
before removing the Refresh.
7) Battery Installation
a)  Remove battery cover from Remote Control 
and insert two (2) AAA batteries (included) 
as shown.
b)  Refasten battery cover with screw.
CAUTION: Use only a 
grounded GFCI outlet!
Press to 
Release
Water Supply Line
T-Valve
L
5
4a
4b
3c
6a
6b
Bidet Hose
7
power
power save
seat heat
seat sensor
EX93000   Refresh Installation Manual  10/06