Installation
M
ASONRY
 C
HIMNEY
 I
NSTALLATION
 - F
REESTANDING
:
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
A  non-combustible  floor  protector  is  required  under  all  freestanding  units;  refer  to  “C
LEARANCES
  T
O
 
C
OMBUSTIBLES
 - 1200 F
REESTANDING
” or “C
LEARANCES
 T
O
 C
OMBUSTIBLES
 - 1700 F
REESTANDING
”. When venting into a 
masonry chimney, the floor protector must be installed directly below the chimney vent and 2” (50.8 mm) 
on either side of the chimney vent.
Vent the stove into a clean, lined, approved masonry chimney in good condition, conforming to local 
building codes and meeting the minimum standards of the National Fire Protection Association (NFPA). 
Make  sure  there  are  no  cracks,  loose  mortar  or  other  signs  of  deterioration  and  blockage.  Have  the 
chimney cleaned before the stove is installed and operated, or vent with a listed 6” (150 mm) factory-
built chimney suitable for use with solid fuels and conforming to ULC-S629 Standard for  650°C factory-
Built Chimneys in CANADA or UL 103 HT Factory-Built Chimneys for Residential Type and Building Heating 
Appliances in the U.S.A. Connect the stove to this chimney with a short and straight 6” (150 mm), 24 
gauge or heavier, single-wall black or blued steel smoke pipe. Connection to all masonry chimneys must 
be a metal or masonry thimble cemented in place. All smoke pipes must slope upwards, all connections 
must be tight and secured with three sheet metal screws equally spaced. The smoke pipe length should 
not exceed 40% of the chimney height above the stove. 
When connecting the stove through a combustible wall to a masonry chimney, additional steps are required. 
Hearth pad.
Floor.
Pedestal
Woodstove
Optional
fan.
Outside air connection
through wall or floor.
All chimneys in Canada must be fully
lined with a 6" (150 mm) stainless
steel liner from the chimney connector
to the top of the chimney.
Chimney thimble; non-combustible (cement
or metal) and must be cemented in place.
Single or listed double
wall chimney connector.
Figure 25: Installation into a masonry chimney.
Figure 26: Installation into chimney through a 
combustible wall.
Consult  the  chimney  connector  manufacturer  and 