For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group
Section 5/Folio MA12-14
Job Information  
Type:
Lightolier is a Philips group brand
Skyway 
SKS2GPK217 or 317
Page 2 of 2
2' x 2' Recessed Fluorescent, Tri-Lens Frame
Static or Air Supply/Return, 2 or 3 Lamp T8
Ordering Information
Explanation of Catalog Number. Example: SKS2GPK217UNVHI
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10 and OA20-30.
Specifications
Performance: In an installation of 2 lamp 17W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .75. To reduce glare the average brightness at 65° shall not exceed
1375 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 67.6%. 
Air Handling: (SKA only) side air passages for air supply or air return. Supply
air is discharged vertically. Optional side closure strips. Air return is also provid-
ed through the lamp compartment through fixture body ends.
MaterialsChassis parts are die-formed code gauge cold rolled steel. Housing has
side rails hemmed over and housing ends turned-in for safe handling.
FinishChassis exterior–black baked polyester enamel. Cavity–white baked
polyester enamel minimum 86% reflectance. Rust preventative undercoating.
Reflectors- 95% reflective white powder coated. 
Specifications (continuned)
Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. 
See: www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (A)
Skyway
Recessed
Fluorescent
Body Style:
= Static
= Air
2
Fixture
Width
Ceiling Type:
= Standard
Grid
= Slot Grid
P
Side Lens:
P= Frost White
Acrylic Lens
17
K
Center Lens:
K
= Pattern 19
.156 Virgin
Acyrlic Lens
0.0
45.0
90.0
FLUX
0
845
845
845
5
839
838
839
80
15
796
797
801
225
25
714
727
752
337
35
602
648
695
405
45
459
477
474
367
55
297
308
287
270
65
171
175
162
175
75
89
86
79
94
85
21
24
17
26
90
7
7
3
Model No. SKS2GPK217UNVHI 
LER = FP - 58.1      IW - 31.7      BF - 0.93
Comparative yearly lighting energy cost per
1000 lumens = $4.13
Report Number: G2008293
Catalog Number: SKS2GPK217UNVHI
Lamps: (2) F17T8/TL835/PLUS/ALTO
Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly.
Ballast: ICN-2P32-SC
Report is based on 1400 Lumens per lamp.
Efficiency: 70.7%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.3
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
21.600
21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
2156.
2240.
2226.
55
1720.
1783.
1662.
65
1344.
1375.
1273.
75
1142.
1103.
1014.
85
800.
914.
648.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 78 75 72 70 68 66 67 66 64
0
2 71 66 61 62 59 56 60 57 54
0
3 65 59 53 55 51 48 53 50 47
0
4 60 52 47 50 45 41 48 44 41
0
5 56 47 41 45 40 36 44 39 36
0
6 52 43 37 41 36 32 40 35 32
0
7 48 39 33 37 32 29 36 32 28
0
8 45 36 30 34 29 26 33 29 26
0
9 42 33 27 32 27 23 31 26 23
10 39 30 25 29 25 21 29 24 21
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
642
22.9
32.4
0
0-
0
40
1047
37.4
52.9
0
0-
0
60
1684
60.1
85.1
0
0-
0
90
1979
70.7
100.0
90-180
000
0
0.0
00
0.0
0
0-180
1979
70.7
100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
0.0
45.0
90.0
FLUX
0
1391
1391
1391
5
1384
1378
1381
131
15
1312
1309
1315
370
25
1175
1172
1166
539
35
984
952
956
602
45
720
714
732
553
55
447
475
435
412
65
260
274
249
269
75
140
131
125
145
85
33
35
28
39
90
12
13
5
Model No. SKS2GPK317UNVH3
LER = FP - 46.8      IW - 46.6      BF - 0.93
Comparative yearly lighting energy cost per
1000 lumens = $5.13
Report Number: G2008296
Catalog Number: SKS2GPK317UNVH3
Lamps: (3) F217T8.TL835/PLUS/ALTO
Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly.
Ballast: ICN-3P32-SC
Report is based on 1400 Lumens per lamp.
Efficiency: 72.9%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.2
1.1
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
21.600
21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
3382.
3353.
3438.
55
2588.
2750.
2519.
65
2043.
2153.
1957.
75
1796.
1681.
1604.
85
1257.
1334.
1067.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 80 77 74 72 70 68 69 68 66
0
2 74 68 64 64 61 58 62 59 56
0
3 68 61 55 57 53 49 55 52 49
0
4 62 54 48 51 47 43 50 46 42
0
5 58 49 43 47 42 38 45 41 37
0
6 53 44 38 42 37 33 41 37 33
0
7 50 40 34 39 34 30 38 33 30
0
8 46 37 31 36 31 27 35 30 27
0
9 44 34 29 33 28 24 32 28 24
10 41 32 26 31 26 22 30 25 22
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
1040
24.8
34.0
0
0-
0
40
1642
39.1
53.7
0
0-
0
60
2607
62.1
85.2
0
0-
0
90
3060
72.9
100.0
90-180
000
0
0.0
00
0.0
0
0-180
3060
72.9
100.0
ZONAL LUMEN SUMMARY
SK
Standard Skyway
SY
For NYC Code – I.B.E.W. Manufactured
NK
For NYC Code – Local 3 Manufactured
Lamp:
(By Others)
17 =T8 17W
(Nominal 24")
Lamp
Quantity
2=2 Lamp
3=3 Lamp
Ballast Type:
Ballast 
<
20THD
<
10THD
Factor
1 or 2 Lamp Elec. T8
SO*
H
I
*
0.88
1-3 Lamp Elec. T8
O3*
H3*
0.88
Advance Optanium
1 or 2 Lamp Elec. T8
C5*
0.80
1 - 3 Lamp Elec. T8
C6*
0.81
LOL Dimming T8
PS
*
*Instant Start Standard
Other dimming options. Consult factory.
NOTE: 
For T8 UNV, you must use H