Листовка для Lightolier H9S2GLR154

Скачать
Страница из 2
HP90 Recessed Fluorescent
H9S2GLR254 or 154
Page 2 of 2
Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR254UNVPGGLR
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK92X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 54W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .88. To reduce glare the average brightness at 65° shall not exceed
3776 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 74.1%. 
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat
white acrylic enamel. Phosphate undercoating. Reflector – low iridescence
specular aluminum 95% reflectance.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
HP90
Direct/Indirect
Recessed
S
Body Style:
= Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
54
Lamp:
(By Others)
54=T5 54W
(Nominal 48")
R
Reflector:
Specular
Aluminum
Lamp
Quantity
1=1 Lamp
2=2 Lamp
Ballast Type:
<
20THD
<
10THD
1 Lamp Elec. T5 HO
PG ††
(54 Watt)
2 Lamp Elec. T5 HO
PG ††
(54 Watt)
††Program Rapid Start (UNV only)
0.0
45.0
90.0
FLUX
0
1393
1393
1393
5
1374
1395
1411
133
15
1323
1360
1366
382
25
1235
1232
1213
566
35
1101
1028
1017
651
45
889
796
818
631
55
598
566
642
529
65
319
390
545
410
75
121
241
317
239
85
10
10
10
24
90
2
2
2
Model No. H9S2GLR154UNVPG
LER = FP - 57.1
IW - 62.4
BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $4.20
Report Number: G2006154
Catalog Number: H9S2GLR154UNVPG
Lamps: F54 T5 HO
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: Advance ICN-2S54 UNV PG
Report is based on 4400 Lumens per lamp.
Efficiency: 81.0%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.3
1.2
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
47.760
23.760
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
1717.
1537.
1580.
55
1424.
1347.
1528.
65
1031.
1260.
1761.
75
638.
1271.
1672.
85
157.
157.
157.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 89 85 82 80 77 75 77 75 73
0
2 81 74 69 70 66 62 67 64 61
0
3 74 66 59 62 57 53 60 55 52
0
4 68 58 51 55 50 45 53 49 45
0
5 63 52 45 50 44 39 48 43 39
0
6 58 47 40 45 39 35 44 38 34
0
7 54 43 36 41 35 31 40 35 31
0
8 50 39 33 38 32 28 37 31 27
0
9 47 36 30 35 29 25 34 29 25
10 44 33 27 32 27 23 31 26 23
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
1081
24.6
30.3
0
0-
0
40
1732
39.4
48.6
0
0-
0
60
2892
65.7
81.1
0
0-
0
90
3566
81.0
100.0
90-180
000
0
0.0
00
0.0
0
0-180
3566
81.0
100.0
ZONAL LUMEN SUMMARY
Model No. H9S2GLR254UNVPG
LER = FP - 66.5
IW - 112.39
BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.61
Report Number: G2006118
Catalog Number: H9S2GLR254UNVPG
Lamps: F54 T5 HO
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: B254UNV-E
Report is based on 4400 Lumens per lamp.
Efficiency: 84.6%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.3
1.4
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
46.800
22.800
0.0
45.0
90.0
FLUX
0
2340
2340
2340
5
2320
2339
2354
223
15
2228
2326
2406
658
25
2079
2280
2417
1044
35
1851
2134
2220
1303
45
1548
1790
1827
1348
55
1173
1345
1428
1197
65
771
963
1099
950
75
383
625
665
597
85
75
95
60
125
90
0
0
0
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
3179.
3676.
3752.
55
2970.
3405.
3615.
65
2649.
3309.
3776.
75
2149.
3507.
3731.
85
1250.
1583.
1000.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 92 88 84 82 79 77 79 77 74
0
2 83 76 70 71 67 63 69 65 61
0
3 76 67 59 63 57 52 60 56 51
0
4 69 59 51 56 49 44 54 48 44
0
5 64 52 45 50 43 38 48 42 38
0
6 59 47 39 45 38 33 43 37 33
0
7 54 43 35 41 34 29 39 34 29
0
8 50 39 32 37 31 26 36 30 26
0
9 47 36 29 34 28 24 33 27 23
10 44 33 26 31 25 21 31 25 21
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
1926
21.9
25.9
0
0-
0
40
3229
36.7
43.4
0
0-
0
60
5774
65.6
77.5
0
0-
0
90
7446
84.6
100.0
90-180
000
0
0
0.0
00
0.0
0
0-180
7446
84.6
100.0
ZONAL LUMEN SUMMARY
Lightolier 
a Genlyte company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 a Genlyte company
Section 5/Folio M32-11
Voltage:
120, 277 or
UNV=120-277
H9
Standard HP90
HY
For NYC Code – I.B.E.W. Manufactured
HN
For NYC Code – Local 3 Manufactured