AFTER USING THE MACHINE
1
Raise the Brush Deck (12).
2
Turn the Master Key Switch (4) OFF.
3
To empty the solution tank, pull the Solution Drain Hose (21) off the elbow Direct the hose to a designated waste water “DISPOSAL SITE”
and remove the plug.  Rinse the tank with clean water.  Inspect the solution hoses; replace if kinked or damaged.
4
To empty the recovery tank, take the Recovery Drain Hose (17) off its hanger. Direct the hose to a designated waste water “DISPOSAL
SITE” and remove the plug (hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled flow of waste water).
Rinse the tank with clean water.  Inspect the recovery and vacuum hoses; replace if kinked or damaged.
5
Remove the Brush (29), rinse with warm water and remove any built-up string, hair or carpet fibers.
6
Disconnect the Recovery Hose (24) from the Recovery Tank Dome Lid (2) and flush with warm water to wash any debris out of the
Recovery Hose / Pick-Up Tool Assembly.  NOTE:  Make sure that you have disconnected the correct hose, if you run water into the vac
motors they will be damaged.
7
Wipe the machine with a damp cloth.  Do not use abrasive chemicals or solvents.
8
Perform any required maintenance before storage.
MAINTENANCE SCHEDULE
MAINTENANCE ITEM
Daily
Weekly
Monthly
Yearly
Charge Batteries
Check / Clean Power Brush
Check / Clean Tanks & Hoses
Check / Clean Vacuum Shut-Off Float
Check / Clean Vacuum Motor Filters
Clean Pick-Up Tools
Clean Spray Nozzles
Check Each Battery Cell(s) Water Level
Inspect Brush Deck Skirt
Inspect & Clean InLine Pump Filter
Lubricate the Machine
*
Check Carbon Brushes
* Have a Nilfisk-Advance service technician check the vacuum motor carbon brushes once a year or after 300 operating hours.  The brush and
drive motor carbon brushes check every 500 hours or once a year.
IMPORTANT!
Motor damage resulting from failure to service the carbon brushes is not covered under warranty.  See the Limited Warranty
Statement.
9
Store the machine in a clean, dry place with the tank dome lid open.