15
english
ATTIX 30/50 H/M
4.3  Cleaning the filter
element
4.3.1  Cleaning the filter
element " Push&Clean
System "
(ATTIX 30- / 50-xx PC)
Only for vacuum cleaning without a 
filter bag and without a cloth insert 
filter.
4.3.2  Cleaning the filter
element " XtremeClean "
(ATTIX 30- / 50-xx XC)
Only for vacuum cleaning without a 
cloth insert filter.
After picking up harmless dust using 
the waste bag.
To ensure that suction perform-
ance  is  always  at  its  best,  the 
filter  element  is  automatically 
cleaned  during  operation.  We 
recommend  complete  cleaning 
if the filter element becomes ex-
tremely dirty.
4.3.3  Check the volume flow
monitor
Before picking up dust with maxi-
mum room concentration values:
Filter Cleaning System
If suction performance drops:
1.  Turn  switch  to  position  "I" 
(maximum suction power).
2.  Close the nozzles or suction 
hose  opening  with  the  palm 
of your hand.
3.  Press the button to start filter 
10 sec.
4.3.4  Acoustic warning
1.  Check  that  all  the  filters  are 
present and properly fitted.
For safety reasons, an acoustic 
warning sounds if the air speed 
in the suction hose drops to be-
cleaning three times. The re-
sulting stream of air removes 
attached  dust  from  the  slats 
of the filter elements.
1.  Switch off the vacuum clean-
er.
2.  Close the nozzles or suction 
hose  opening  with  the  palm 
of your hand.
3.  Turn the switch to position „I“ 
and  let  the  cleaner  operate 
for  approx.  10  seconds  with 
the  suction  hose  opening 
closed.
2.  When  the  motor  is  run-
ning, hold the suction hose 
shut.  An  acoustic  warning  
sounds after approx. 1 sec-
ond.
low  20  m/s.  See  section  "Trou-
bleshooting"