86306300 CHARIOT BURNISHER  11/09/07 
4-4 
 
CHECKING BATTERY SPECIFIC GRAVITY 
 
Use a hydrometer to check the battery specific 
gravity.   
 
 
 
 
 
 
 
 
 
 
 
 
 
CHECKING GRAVITY 
A.  Hydrometer 
B. Battery 
 
NOTE:
  Do not take readings immediately after 
adding distilled water, if the water and acid are not 
thoroughly mixed, the reading may not be accurate. 
 
Check the hydrometer readings against this chart. 
 
SPECIFIC GRAVITY 
@ 80
°
 F (27
°
C) 
BATTERY CONDITION 
1.265 100% 
CHARGED 
1.225 75% 
CHARGED 
1.190 50% 
CHARGED 
1.155 25% 
CHARGED 
1.120 DISCHARGED 
 
NOTE:  If the readings are taken when the battery 
electrolyte is any temperature other than 80
°
(27°C), the reading must be temperature corrected. 
 
To find the corrected specific gravity reading when 
the temperature of the battery electrolyte is other 
than 80°F (27°): Add (+) to the specific gravity 
reading 0.004 (4 points), for each 10°F (6°C) above 
80° (27°C).   
Subtract (-) from the specific reading 0.004 (4 
points), for each 10°F (6°C) below 80°F (27°C). 
 
 
 
 
 
 
 
 
 
 
 
 
 
CHARGING BATTERIES 
 
When servicing machine, 
avoid contact with battery 
acid. 
 
Batteries emit hydrogen 
gas.  Explosion or fire can 
result.  Keep sparks and open flame away.  Keep 
covers open when charging. 
 
Wear eye protection and 
protective clothing when  
working with batteries. 
 
Charge batteries in a well 
ventilated area. 
 
Use a 36 volt, 20 amp maximum output DC charger 
which will automatically shut off when the batteries 
are fully charged. 
 
1. Stop the machine in a clean, well ventilated area 
next to the charger.   
 
2. Turn “OFF” machine. 
 
FOR SAFETY:  Before leaving or servicing 
machine; stop on level surface, turn off machine 
and remove key. 
 
3. Remove rear cover, unplug batteries from 
machine, unlatch battery tray and pull out to 
expose batteries. 
 
Batteries emit hydrogen 
gas.  Explosion or fire 
can result.  Keep sparks and open flame away.  
Keep covers open when charging. 
 
4. Check the electrolyte level in each battery cell.  
Before charging, add just enough distilled water 
to cover the plates.  After charging is complete, 
add just enough distilled water to bring up the 
level to the indicator ring.  If the water level is 
too high before charging, normal expansion rate 
of the electrolyte may cause an overflow 
resulting in a loss of battery acid balance and 
damage the machine. 
 
 
 
 
 
Battery Check