properly. To prevent water damage, the valve must be 
properly connected to a discharge line which terminates at 
an adequate drain. Standing clear of the outlet (discharged 
water may be hot), slowly lift and release the lever handle 
on the temperature and pressure relief valve to allow the 
valve to operate freely and return to its closed position. 
See Figure 21. If the valve fails to completely reset and 
continues to release water, immediately shut off the 
manual gas control valve and the cold water inlet valve 
and call a qualified technician.
TEMPERATURE AND PRESSURE
RELIEF VALVE
DISCHARGE LINE TO DRAIN
MANUAL RELIEF
VALVE
FIGURE 21.
4.  Remove the outer door.
5.  Remove the two screws securing the manifold door 
assembly to the combustion chamber (Figure 23).
MANIFOLD 
SCREWS (2)
TWO PIECE 
WIRE CONNECTOR
MANIFOLD 
DOOR
THERMAL
SWITCH
PILOT
TUBE
PIEZO
IGNITER
BUTTON
GAS CONTROL VALVE/
THERMOSTAT
MANIFOLD 
TUBE
THERMOCOUPLE
VIEW PORT
FIGURE 23.
6.  Disconnect the thermocouple (right-hand thread), pilot 
tube, the igniter wire from the igniter button, the two 
connectors attached to the thermal switch, and manifold 
tube at the gas control valve/thermostat. (Figures  22 
& 23.) NOTE: L.P. Gas systems use reverse (left-hand) 
threads on the manifold tube. 
7.  Grasp the manifold tube and push down slightly to free the 
manifold, pilot tube, and thermocouple.
8.  Carefully remove the manifold/burner assembly from the 
burner compartment. NOTE: Be sure not to damage 
internal parts. 
Removing the Burner from the Manifold/
Burner Assembly                                                      
Natural Gas (Low Nox) & L.P. Gas Burner
1.  Take off the burner by removing the two (2) screws 
located underneath the burner.
Replacement Parts                                                      
IMPORTANT: The following maintenance procedures are 
for the FVIR System components and should be performed 
by a qualified technician.
Replacement parts may be ordered through your plumber 
or the local distributor. Parts will be shipped at prevailing 
prices and billed accordingly. When ordering replacement 
parts, always have the following information ready:
1.  model, serial, and product number
2.  type of gas
3. item 
number
4. parts 
description
See Repair Parts Section for a list of available repair parts.
Removing  the  Manifold/Burner  Assembly                                                     
1.  Turn off the gas supply to the water heater at the manual 
gas shut-off valve. This valve is typically located beside 
the water heater. Note the position of the shut-off valve in 
the open/on position then proceed to turn it off (Figure 3).
2.   On the lower front of the water heater locate the gas 
control valve/thermostat (see Figure 23). Before per-
forming any maintenance, it is important to turn the 
temperature dial on the gas control valve/thermostat to 
its lowest setting.
3.   On top of the gas control valve/thermostat turn the gas 
control knob to the “OFF” position. NOTE: On the White 
Rodgers gas control valve/thermostat the knob stop must 
first be depressed before turning the gas control knob. 
See Lighting Instructions on the water heater.(Figure 19).
THERMOCOUPLE 
MANIFOLD TUBE 
PILOT  
TUBE 
WHITE RODGERS GAS VALVE
 
ROBERTSHAW GAS VALVE 
THERMOCOUPLE 
MANIFOLD TUBE 
PILOT  
TUBE 
FIGURE 22.
Temperature  and  Pressure  Relief  Valve                    
Explosion Harzard
• Temperature-pressure relief 
valve must comply with ANSI 
Z21.22-CSA 4.4 and ASME 
code.
•  Properly sized temperature-
pressure relief valve must be 
installed in opening provided.
•  Can result in overheating 
and excessive tank pressure.
•  Can cause serious injury or 
death.
Manually operate the temperature and pressure relief 
valve at least once a year to make sure it is working 
MAINTENANCE OF YOUR WATER HEATER