2
©
TEST 3 - CONTINUITY CHECK OF HIGH LIMIT (ECO)
Conditions:
●
Power On – No Hot Water
●
Red, heater control “Call for Heat”
LED – on
●
Red ignition control board
diagnostic LED – 4 Flashing
●
Note LED Flash Code before
resetting water heater control.
●
See Description of diagnostic LED
Flashes.
●
Turn Power “Off”
0.0
Ohms
TEST 3
Continuity check of ECO (energy cut-off, high limit)
Black to Black wires of upper probe. Power is off.
Black to Black wires of upper probe. Power is off.
..
..
.
n
e
h
t
…
fI
continuity
is indicated (ZERO “0.0” Resistance)
opens at 203° F; closes at 193° F. If water is
below 193° F, continuity is correct.
continuity
is not present (meter reads “0.L”)
replace ECO sensor, if water temperature is
below 193° F.
.
n
o
e
b
d
l
u
o
h
s
D
E
L
s
u
t
a
t
s
t
e
s
e
r
•
F
°
0
2
1
n
a
h
t
s
s
e
l
s
i
r
e
t
a
w
•replace heater control if control will not manually
reset.