LP Gas Only                                                                    
WARNING
Explosion Hazard
Have a qualified person make sure L.P. gas pressure 
does not exceed 13” water column.
Examples of a qualified person include: licensed 
plumbers, authorized gas company personnel, and 
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
  
                                              
Liquefied petroleum gas is over 50% heavier than air 
and in the occurrence of a leak in the system, the gas 
will settle at floor level. Basements, crawl spaces, closets 
and areas below ground level will serve as pockets for 
the accumulation of gas. Before lighting an L.P. gas water 
heater, smell all around the appliance at floor level. If you 
smell gas, follow the instructions as given in the warning 
on the front page.
When your L.P. tank runs out of fuel, turn off the gas at 
all gas appliances including pilot lights. After the tank is 
refi lled, all appliances must be re-lit according to their 
manufacturer’s instructions.