Листовка для Rheem RH DV50FV

Скачать
Страница из 2
These units are designed
to meet or exceed ANSI
(American National
Standards Institute)
requirements and have been
tested according to D.O.E.
test procedures and meet or
exceed the energy efficiency
requirements of NAECA,
ASHRAE standard 90, ICC
Code and all state energy
efficiency performance
criteria for energy consuming
appliances.
Before purchasing this
appliance, read important
energy cost and efficiency
information available from
your supplier.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.
G
E
A
B
C
F
D
10"
3/4" N.P.T.
RELIEF VALVE
OPENING
1/2"
EXTERIOR
WALL
(G:
SIDE VENTING
 
RANGE OF
ADJUSTMENT)
Fury DV
Available in 50 Gallon Gas Model
6-Year Limited Tank Warranty, 1-Year Limited Parts Warranty*
NEW FVIR Compliant!
Adjustable coaxial vent allows flexibility
of installation – uses outside air for combustion
and requires no electrical power
Aluminum vent and cap base to prevent
staining of building exterior
Brass drain valve
Factory installed temperature and pressure
relief valve
R-Foam
®
insulation for superior heat retention
Exclusive Rheemglas
®
tank lining resists
corrosion and prolongs tank life
Heat saving flue baffle design
Gas control and combination thermostat
Anode rod equalizes aggressive water action
High temperature silicone bands reduce venting
installation time
Internal air tube for reduced footprint
Meets ANSI Z21.10.1 requirements for
Flammable Vapor Ignition Resistance (FVIR)
Meets or exceeds National Appliance Energy
Conservation Act (NAECA) requirements
* See Residential Warranty Information Brochure for complete
warranty information.
Energy Factor based on D.O.E. (Department of Energy) test procedures.
DESCRIPTION
FEATURES
DIMENSIONS
ENERGY INFO.
GAS INPUT IN
RECOVERY IN
FIRST HOUR
HT. TO
TANK
HT. TO
VENT
HT. TO
SHIP.
ENERGY
GALLON
MODEL
THOUS. BTU/HR.
G.P.H. 90° RISE
DEL. G.P.H.
VENT
HT.
DIAMETER
GAS CONN.
SIZE
SIDE T&P
WT.
FACTOR
CAPACITY
NUMBER
NAT.
NAT.
NAT.
A
B
C
D
E
F
(LBS)
NAT.
50
RH DV50FV
38
38.4
80
68
59-1/2
21-3/4
14-1/4
6
52-1/2
165
0.58
HOT WATER
CONNECTION
COLD WATER
CONNECTION
ANODE
LONGER VENTING AVAILABLE
Rheem Exclusive Adjustable
Coaxial Vent Allows Flexibility
of Installation…
You may orient the Fury DV
for easiest service
access, because the
adjustable coaxial
vent can swivel
360 degrees.
NEW LONGER VENTING!
• Up to 4 feet above the water heater
and 4 feet from an outside wall.
Order Horizontal Vent Kit:
#SP20131
Order Vertical Vent Kit:
#SP20132
RH DV50FV
Horizontal & Vertical
8-1/8
18-1/8
8-1/8
48**
68 – 107†
VENTING – ROUGHING IN DIMENSIONS (INCHES)
MODEL
4 FEET VENTING
OPTIONAL HEIGHT (A)
NUMBER
AVAILABLE
MIN.
MAX.
MIN.
MAX.
WITH VENT KIT
SIDE VENTING (G)
WITH INCLUDED
VENT KIT
SIDE VENTING (G)
WITH OPTIONAL
VENT KIT
Rheemglas
®
Energy Miser
®
Direct Vent Gas Water Heaters
now with the Guardian System
®
Rheem Manufacturing Company • Water Heater Division
Rheem Canada Ltd./Ltée
, 128 Barton Street West, Hamilton, Ontario L8N 3P3
1 2 / 0 7 W P
F O R M N O . 1 0 1 - 2 2 E F C A N R e v 1
** Horizontal Vent Kit #SP20131. Venting dimensions are approximate.
† Vertical Vent Kit #SP20132. Venting dimensions are approximate.
• If side wall is combustible material, 1" clearance must be included in adjustment range.