PATENTS 
This water heater may be protected by one or more patents or registered designs. 
 
® Registered trademark of Solahart Industries Pty Ltd or Rheem Australia Pty Ltd. 
™ Trademark of Solahart Industries Pty Ltd or Rheem Australia Pty Ltd. 
 
 
 
 
 
Notice to Victorian Customers from the 
Victorian Plumbing Industry Commission.
 
This water heater must be installed by a licensed person as required by the 
Victorian Building Act 1993. 
Only a licensed person will give you a Compliance Certificate, showing that the work complies with all 
the relevant standards. Only a licensed person will have insurance protecting their workmanship for 6 
years. Make sure you use a licensed person to install this water heater and ask for your Compliance 
Certificate. 
 
 
 
 
 
WARNING: Plumber – Be Aware 
•  The solar hot and solar cold pipes between the solar storage tank and the solar 
collectors  MUST BE of copper and fully insulated with closed cell polymer 
insulation or similar (minimum thickness 13 mm). Thicker insulation may be 
required to comply with the requirements of AS/NZS 3500.4. The insulation must 
be weatherproof and UV resistant if exposed. All compression fittings must use 
brass or copper olives. 
Note: Failure to observe this requirement increases the risk of freeze 
damage. 
• Plastic 
pipe 
MUST NOT be used, as it will not withstand the temperature and 
pressure of the water generated by the solar collectors under stagnation 
conditions. The solar collectors can generate extremely high water temperatures 
up to 150
°C and high water pressure of 1000 kPa. Plastic pipe cannot withstand 
these temperatures and pressures and MUST NOT be used. Failure of plastic pipe 
can lead to the release of high temperature water and cause severe water damage 
and flooding. 
27
•  A non return valve MUST BE installed on the cold water line to the solar storage 
tank AFTER the cold water branch to a temperature limiting device.