INSTALLATION – SOLAR STORAGE TANK 
21 
REDUCING HEAT LOSSES 
The cold water line to and the hot water line from the water heater must be insulated in accordance with 
the requirements of AS/NZS 3500.4. The insulation must be weatherproof and UV resistant if exposed. 
 
The pipe work between the solar storage tank and the solar collectors must be fully insulated with 
closed cell polymer insulation or similar (minimum thickness 13 mm). Thicker insulation may be 
required to comply with the requirements of AS/NZS 3500.4. The insulation must be weatherproof and 
UV resistant if exposed. The insulation must be fitted up to the connections on both the solar storage 
tank and the solar collectors. 
 
ANODE TYPES 
The correct anode type for the water supply being used must be fitted in the water heater (refer to 
 on page 36). The black anode is fitted as standard. 
 
Total Dissolved Solids in water supply to the water heater 
Anode colour code 
0 – 40 mg/L 
Green 
40 – 600 mg/L 
Black 
600 – 2500 mg/L 
Blue 
 
SADDLING - PIPE WORK 
To prevent damage to the cylinder when attaching pipe clips or saddles to the water heater jacket, we 
recommend the use of self-drilling screws with a maximum length of 12 mm. Should pre drilling be 
required, extreme caution must be observed when penetrating the jacket of the water heater. 
 
Note: Damage to the cylinder as a result of saddling to the jacket will void the warranty. 
 
BOOSTER HEATING UNIT 
The booster heating unit provides hot water during periods of low solar gain. This can be connected to 
either an Off-Peak (overnight), Extended Off-Peak (overnight and day) electricity supply or a continuous 
electricity supply. Boosting can be controlled via a user operated manual switch. Refer to 
 on page 31
 
If this water heater is installed as a solar preheater to an in-series water heater, then the booster 
heating unit does not need to be connected to a power supply.