Справочник Пользователя для Rheem HE80-130N

Скачать
Страница из 30
2
SPECIFICATIONS
DIMENSIONAL INFORMATION
All dimensions shown in English and Metric
MODEL
WATER CONNECTIONS
APPROX
NUMBER
UNITS
HEIGHT
WIDTH
DEPTH
VENT
INLET
OUTLET
SHIPPING WT.
inches
42
23 1/2
32
2
1
1
175 lbs.
mm
1067
597
813
51
25
25
79 kgs
inches
42
23 1/2
32
3
1
1
175 lbs.
mm
1067
597
813
76
25
25
79 kgs
inches
72
23 1/2
32
3*
1-1/2
1-1/2
235 lbs.
mm
1854
597
813
76
38
38
106 kgs
inches
73
27
36
3*
1-1/2
1-1/2
405 lbs.
mm
1854
686
914
76
38
38
184 kgs
All models require a 120V power source.
* 130,000 Btu models are certified to be installed with 2” venting.
HE45-100
HE45-130
HE45-160
HE45-199
HE80-130
HE80-160
HE80-199
HE119-130
HE119-160
HE119-199
RECOVERY CAPACITIES
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises
MODEL
INPUT (BTU/HR)
THERMAL
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F
120°F
NUMBER
NAT. & LP
EFFICIENCY
UNITS
(22.2°C)
(27.8°C)
(33.3°C)
(38.9°C)
(44.4°C)
(50.0°C)
(55.6°C)
(61.1°C)
(66.7°C)
100,000
95%
GPH
288
230
192
165
144
128
115
105
96
LPH
1090
872
726
623
545
484
436
396
363
130,000
95%
GPH
374
299
249
214
187
166
150
136
125
LPH
1417
1133
944
809
708
630
567
515
472
160,000
95%
GPH
461
368
307
263
230
205
184
167
154
LPH
1744
1395
1162
996
872
775
697
634
581
199,000
95%
GPH
573
458
382
327
286
255
229
208
191
LPH
2169
1735
1446
1239
1084
964
867
789
723
Recovery rating is based on thermal efficiencies obtained in an AGA certified laboratory. 
0" CLEARANCE TO
COMBUSTIBLES ON ALL
ADVANTAGE PLUS UNITS,
HOWEVER, A 24"
CONTROL PANEL SER-
VICE CLEARANCE IS
RECOMMENDED.
HE45-100
HE45-130
HE80-130
HE119-130
HE80-160
HE119-160
HE80-199
HE119-199
BOOSTER MODELS 
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH)
MODEL
INPUT (BTU/HR)
THERMAL
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F
120°F
130°F
140°F
NUMBER
NAT. & LP
EFFICIENCY
UNITS
(22.2°C)
(27.8°C)
(33.3°C)
(38.9°C)
(44.4°C)
(50.0°C)
(55.6°C)
(61.1°C)
(66.7°C)
(72.2°C)
(77.8°C)
HE45-160
160,000
95%
GPH
461
368
307
263
230
205
184
167
154
142
132
LPH
1744
1395
1162
996
872
775
697
634
581
536
498
HE45-199
199,000
95%
GPH
573
458
382
327
286
255
229
208
191
176
164
LPH
2169
1735
1446
1239
1084
964
867
789
723
667
620
All models exceed the minimum NAECA energy efficiency requirements of ASHRAE 90.1b-1989, 1992 requirements.
MAXIMUM DELIVERY
In U.S. Gallons and Liters (Includes useable storage and recovery for indicated times)
MODEL
GALLONS/
MAX.
INPUT (BTU/HR)
TEMP.
5
10
15
20
30
45
1
2
3
MIN. TO RECOVER
NUMBER
LITERS
SETPOINT
NAT. & LP
RISE
UNITS
MIN.
MIN.
MIN.
MIN.
MIN.
MIN.
HR.
HR.
HR.
CONTENTS
HE45-100
45
160º
100,000
100°F
GAL.
41
51
60
70
89
118
147
262
377
23
170
55.6°C
LTR.
156
192
228
265
337
446
555
991
1427
HE45-130
45
160º
130,000
100°F
GAL.
44
56
69
81
106
144
181
331
481
18
170
55.6°C
LTR.
166
214
261
308
403
544
686
1253
1819
HE80-130
80
160º
130,000
100°F
GAL.
68
81
93
106
131
168
206
355
505
32
303
55.6°C
LTR.
259
306
354
401
495
637
779
1345
1912
HE119-130
119
160º
130,000
100°F
GAL.
96
108
121
133
158
196
233
383
532
48
450
55.6°C
LTR.
363
410
457
504
599
750
882
1449
2015
HE45-160
45
180º*
160,000
100°F
GAL.
47
62
78
93
124
170
216
400
584
15
170
55.6°C
LTR.
177
235
294
352
468
642
817
1514
2211
HE80-160
80
160º
160,000
100°F
GAL.
71
87
102
117
148
194
240
424
609
26
303
55.6°C
LTR.
270
328
386
444
561
735
909
1607
2304
HE119-160
119
160º
160,000
100°F
GAL.
99
114
129
145
175
221
268
452
636
39
450
55.6°C
LTR.
373
432
490
548
664
838
1013
1710
2408
HE45-199
45
180º*
199,000
100°F
GAL.
51
70
89
108
146
203
261
490
719
12
170
55.6°C
LTR.
192
264
336
408
553
770
987
1854
2721
HE80-199
80
160º
199,000
100°F
GAL.
75
94
113
132
171
228
285
514
743
21
303
55.6°C
LTR.
284
357
429
501
646
863
1079
1947
2814
HE119-199
119
160º
199,000
100°F
GAL.
102
121
141
160
198
255
312
542
771
31
450
55.6°C
LTR.
338
460
532
604
749
966
1183
2050
2918
All models have a maximum setpoint of 160°F with the exception of the HE45-160 and HE45-199 booster models. The HE45-160 and HE45-199 have a maximum setpoint of 180°F.
* NOTE: The 180º F models are shipped with all necessary components for an approved installation (see Booster Installation Kit for component list.)