Recommended Specifications (for trade reference only)
Water heater(s) shall be RHEEM-RUUD model ________________, having electrical input of __________ kW. Water heater(s) shall
have a storage capacity of ___________ gallons. Water heater(s) shall have the UL seal of certification and have a factory supplied
AGA/ASME rated temperature and pressure relief valve. Tank(s) shall have a coating of high temperature porcelain enamel and
furnished with magnesium anode rods rigidly supported. Water heater(s) shall meet or exceed the standby loss requirements of
ASHRAE. Tank(s) shall have a working pressure of 125 psi, and shall be completely assembled. Water heater(s) shall be approved-
listed and constructed in accordance with UL 1453. Water heater(s) shall be equipped with “screw-in” type elements featuring a
stainless steel outer sheath of INCO-LOY material. Tank shall be insulated with rigid polyurethane foam insulation. Water heater(s)
shall be provided with internal power circuit fusing, control circuit fusing, magnetic contactors, 120 volt control circuit transformer and
immersion thermostat(s) with manual reset high limit control. Water heater(s) shall be covered by a three year limited warranty
against tank leaks. Water heater(s) shall be constructed in accordance with the requirements of the ASME Boiler and Pressure
Vessel Code, Section IV Part HLW.
Limited Warranty:
This product features a three year limited warranty against tank leaks. Please refer to
Commercial Warranty Information brochure for complete warranty information.
Large Volume Electric continued.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
Rheem Canada Ltd./Ltée,128 Barton Street West, Hamilton, Ontario L8N 3P3
P R I N T E D I N U . S . A
1 0 / 0 7 W P
F O R M N O . R R 1 0 2 C E - 8
In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.
Standard KW Input and Amperage
SUGGESTED
GPH @
MAX.
NO. OF
KW
NO OF
MODULATING
AMPERAGE DRAW
KW
100° F
BTU/HR
NO. OF
CONTROL
PER
CONTACTORS
CONTROL STEP
SINGLE PHASE
THREE PHASE
INPUT
RISE
EQUIVALENT
ELEMENTS
STEPS
ELEMENT
240/480V
208/240V
208V
240V
208V
240V
480V
12
49
40,944
1
1
12
2/1
58
50
33
29
14
15
62
51,180
1
1
15
2/1
72
63
42
36
18
18
74
61,416
1
1
18
2/1
87
75
50
44
22
30
123
102,360
2
1
15
2/1
144
125
83
72
36
36
148
122,832
2
1
18
4/2
4/2
174
150
100
87
44
45
185
153,540
3
1
15
3/2
3/2
216
188
125
108
54
54
221
184,248
3
1
18
6/2
3/2
260
225
150
130
65
60
246
204,720
4
2
15
12/6
4/3
289
250
167
144
72
72
295
245,664
4
2
18
8/4
4/4
200
174
87
90
369
307,080
5
2
18
6/3
3/3
250
217
109
108
443
368,496
6
2
18
12/4
4/4
300
260
130
120
492
409,440
8
3
15
8/4
4/4
333
289
144
135
554
460,620
9
3
15
9/6
4/4
375
325
162
144
590
491,328
8
3
18
16/8
4/4
400
347
174
162
664
552,744
9
3
18
18/6
8/6
450
389
186
180
738
614,160
10
4
18
20/10
8/8
500
434
217
216
886
736,992
12
4
18
24/8
8/8
600
519
260
234
959
798,408
13
5
18
26/13
8/8
650
563
282
252
1,033
859,824
14
5
18
28/14
8/8
700
607
304
270
1,107
921,240
15
5
18
30/10
12/10
750
649
325
288
1,181
982,656
16
6
18
32/16
12/12
800
692
347
306
1,255
1,044,072
17
6
18
34/17
12/12
850
736
368
324
1,328
1,105,488
18
6
18
36/12
12/12
900
780
390
342
1,402
1,166,904
19
7
18
38/19
12/12
950
822
412
360
1,476
1,228,320
20
7
18
40/20
12/12
1,000
865
435
378
1,550
1,289,736
21
7
18
42/14
14/14
1,050
909
455
396
1,624
1,351,152
22
8
18
44/22
15/16
1,100
952
477
414
1,697
1,412,568
23
8
18
46/23
16/16
1,150
995
498
432
1,771
1,473,984
24
8
18
48/16
16/16
1,200
1,040
520