Листовка для Rheem 75

Скачать
Страница из 2
DIMENSIONAL INFORMATION
APPROX.
MODEL
SHIPPING
NUMBER
UNITS
A
B
C
D
E
F
G
H
WEIGHT
STID30
inches
22
35-3/4
27-3/4
18-1/2
11-3/4
6-1/2
4-1/2
N/A
180 lbs
STID40
inches
22
42-3/4
34-3/4
31-1/2
16-3/4
6-1/2
4-1/2
N/A
226 lbs
STID50
inches
22
48-3/4
39-3/4
31-1/2
16-3/4
6-1/2
4-1/2
N/A
231 lbs.
STID80
inches
24
64-1/8
57-1/8
33
19-1/4
8
5
5
297 lbs.
STID120
inches
28
65-1/4
57-3/4
33-3/4
16-1/4
8-3/4
5
6-1/2
397 lbs.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
P R I N T E D I N U . S . A
0 5 / 0 8 W P
F O R M N O . R R 1 0 2 C - 3 I D
In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.
Indirect Coil Tank continued.
STID80 & STID120
FIRST HOUR RATING (gal) @ Coil Output (Btu/hr)
TANK
FIRST
HEAT SOURCE
MODEL
CAPACITY
DRAW
FRICTION LOSS*
180°F,
180°F,
180°F,
200°F,
200°F,
200°F,
NUMBER
(GAL)
(GAL)
(FT. W.C.)
8 GPM**
10 GPM**
12 GPM**
8 GPM**
10 GPM**
12 GPM**
STID30
30
25
2
110 @ 55,000
114 @ 57,000
117 @ 59,000
132 @ 69,000
136 @ 71,000
139 @ 73,000
STID40
38
33
3
153 @ 77,000
165 @ 84,000
177 @ 92,000
183 @ 96,000
195 @ 104,000
207 @ 111,000
STID50
45
40
3
160 @ 77,000
172 @ 84,000
184 @ 92,000
190 @ 96,000
202 @ 104,000
214 @ 111,000
STID80
75
70
5
200@83,000
212 @ 91,000
224 @ 98,000
233 @ 104,000
245 @ 112,000
257 @ 119,000
STID120
110
102
5
232@83,000
244 @ 91,000
256 @ 98,000
265 @ 104,000
277 @ 112,000
289 @ 119,000
All data obtained through testing in accordance with GAMA INDIRECT-FIRED WATER HEATERS TESTING STANDARD IWH-TS-1_MARCH 2003
* At 8 GPM
**Coil Input (temperature, flow rate). Ratings based on 77°F rise with 58°F inlet potable water.
Note: First Hour Rating = First Dray + Continuous Draw
Warning: Installation should be in accordance with all national and/or local codes.
In the absence of local codes, refer to NFPA 54 or ANSI Z.21.10.1.
Caution: The recommended maximum hot water temperature setting for normal residential use is 120°F. Rheem recommends a tempering
valve or anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.
Pressures (all): Test pressure, 300 psi; working pressure, 150 psi
Standard Voltage (all): 120V, 60 Hz, 1P
T&P valve installed
STID30, STID40
& STID50
G
H
A
E
F
D
C
B
Cold Inlet, 1" NPT
Hot Outlet,
1-1/2" NPT
Anode Rod
Anode
Rod
T&P Relief Valve
From Boiler,
1" NPT
To Boiler, 
1"NPT
Drain Valve
Aquastat
G
Cold Inlet, 
3/4" NPT
Hot Outlet/
Anode Rod,
3/4" NPT
Anode Rod
Aquastat
T&P Relief Valve
From Boiler, 1" NPT
To Boiler,
1" NPT
Drain Valve
F
D
C
E
B
A
WATER HEATERS
Limited Warranty
This product features a six year limited warranty against tank leaks when installed in
residential applications and three year limited warranty against tank leaks when
installed in non-residential applications. Please refer to the Warranty Information
document for complete warranty information.