Справочник Пользователя для Rheem 85 Gallon

Скачать
Страница из 4
Heavy Duty Electric continued.
RECOVERY CAPACITIES 
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises
INPUT
EQUIVALENT
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F 120°F
130°F 140°F
KW
BTU/HR.
UNITS
(22°C)
(28°C)
(33°C)
(39°C)
(45°C)
(50°C)
(56°C)
(61°C)
(67°C)
(72°C)
(78°C)
6
20,473
GPH
62
50
41
35
31
28
25
23
21
19
18
LPH
235
188
157
134
117
104
94
85
78
72
67
9
30,709
GPH
93
74
62
53
47
41
37
34
31
29
27
LPH
352
282
235
201
176
157
141
128
117
108
101
12
40,946
GPH
124
99
83
71
62
55
50
45
41
38
35
LPH
470
376
313
268
235
209
188
171
157
145
134
15
51,183
GPH
155
124
103
89
78
69
62
56
52
48
44
LPH
587
470
391
335
294
261
235
213
196
181
168
18
61,420
GPH
186
149
124
106
93
83
74
68
62
57
53
LPH
705
564
470
403
352
313
282
256
235
217
201
24
81,893
GPH
248
199
165
142
124
110
99
90
83
76
71
LPH
939
751
626
537
470
417
376
342
313
289
268
27
92,129
GPH
279
223
186
160
140
124
112
102
93
86
80
LPH
1057
845
705
604
528
470
423
384
352
325
302
30
102,366
GPH
310
248
207
177
155
138
124
113
103
95
89
LPH
1174
939
783
671
587
522
470
427
391
361
335
36
122,839
GPH
372
298
248
213
186
165
149
135
124
115
106
LPH
1409
1127
939
805
705
626
564
512
470
434
403
45
153,549
GPH
465
372
310
266
233
207
186
169
155
143
133
LPH
1761
1409
1174
1006
881
783
705
640
587
542
503
54
184,259
GPH
558
447
372
319
279
248
223
203
186
172
160
LPH
2114
1691
1409
1208
1057
939
845
769
705
650
604
81
276,388
GPH
838
670
558
479
419
372
335
305
279
258
239
LPH
3174
2540
2116
1814
1587
1410
1270
1154
1058
977
907
INPUT
KW
NO.
OF
ELE-
MENTS
ELE-
MENT
WAT-
TAGE
FULL LOAD CURRENT
IN AMPERES
208V
Phase
1      3
240V
Phase
1      3
277V
Phase
1     
480V
Phase
1     3
IMMERSION THERMOSTATS
Number
of
Contactors
Number
of
Fuses
Staged T’Stats
No. of
T’Stats
KW Step
Size
Thermostat Staging – 
On all immersion thermostat
models, 24 kW and above 
(18kW for 208V), additional 
thermostats can be provided 
so that the maximum element
input will not exceed 18 kW - 
27 kW per step. Temperature
differential between steps can 
be set as desired.
Note: Thermostat staging
recommended on 81kW models.
No.
of
T’Stats
Number
of
Fuses
SURFACE MOUNTED
WATER TEMPERATURE RATINGS
Minimum
Maximum
High
Model
Tank Capacity
Thermostat
Delivered
Delivered
Temperature
Number
Gallons     Liters
Type
Temperature Temperature
Limit
ES50
50
189
Surface
90°F
160°F
180°F
32.2°C
71.1°C
82.2°C
ES85
85
322
Surface
120°F
160°F
190°F
48.8°C
71.1°C
87.8°C
ES120
119.9
454
Surface
120°F
160°F
190°F
48.8°C
71.1°C
87.8°C
E50
50
189
Immersion
90°F
190°F
200°F
32.2°C
87.8°C
93.3°C
E85
85
322
Immersion
90°F
190°F
200°F
32.2°C
87.8°C
93.3°C
E120
119.9
454
Immersion
90°F
190°F
200°F
32.2°C
87.8°C
93.3°C
N/A
ONE
T’STAT
STD.
6
3
2000
29
17
25
14
22
13
7
1
6
2
6
1
6
9
3
3000
43
25
38
22
33
19 11
1
6
2
6
1
9
12
3
4000
58
33
50
29
43
25 15
1
6
2
6
12
15
3
5000
72
42
63
36
54
31 18
1
6
2
6
15
18
3
6000
75
43
65
38 22
1
6
2
6
18
18
6
3000
87
50
1
12
4
12
2
1
9
24
6
4000 116 67 100 58
87
50 29
1
12
4
12
2
12
27
6
4500 130 75 113 65
98
56 33
1
12
4
12
2
13.5
30
6
5000 144 84 125 73
108
63 36
1
12
4
12
2
15
36
6
6000
150 87
130
75 43
1
12
4
12
2
18
36
9
4000 173 100
1
18
6
18
3
12
45
9
5000 217 125 188 109
163
94 54
1
18
6
18
3
15
54
9
6000 260 150 225 130
195
113 65
1
18
6
18
3
18
81
9
9000
169 98
18
3
27