INSTALLATION 
 
THIS WATER HEATER IS FOR OUTDOOR INSTALLATION ONLY. 
THIS WATER HEATER IS NOT SUITABLE FOR POOL HEATING. 
Check the water heater is suitable for the gas type available 
(refer to the rating label on the water heater). 
 
WATER HEATER LOCATION 
The water heater should be installed close to the most frequently used outlet 
and its position chosen with safety and service in mind. Make sure people 
(particularly children) will not touch the flue outlet. The flue terminal must be 
clear of obstructions and shrubbery. 
 
Clearance must be allowed for servicing 
of the water heater. The water heater 
must be accessible without the use of a 
ladder or scaffold. Make sure the 
temperature pressure relief valve lever 
is accessible and the front cover and 
burner can be removed for service. 
 
If possible leave headroom of one water 
heater length so the anode can be 
inspected or replaced. Remember you 
may have to remove the entire water 
heater later for servicing. 
 
The installation must comply with the 
requirements of AS/NZS 
3500.4, 
AS 
5601 and all local codes and 
regulatory authority requirements. In 
New Zealand, the installation must 
conform with NZS 
5261 Code of 
Practice for Installation of Gas Burning 
Appliances and the New Zealand 
Building Code. 
 
The water heater must not be installed in an area with a corrosive atmosphere 
where chemicals are stored or where aerosol propellants are released. 
Remember the air may be safe to breathe, but when it goes through a flame, 
chemical changes take place which may attack the water heater.