SAVE A SERVICE CALL 
 
Check the items below before making a service call. You will be charged for 
attending to any condition or fault that is not related to manufacture or failure of 
a part. 
 
NOT ENOUGH HOT WATER (OR NO HOT WATER) 
This can occur with new installations and is normally related to some 
misunderstandings as to the use of the timer and gas booster. 
• 
Insufficient sunlight 
Insufficient sunlight due to cloudy 
weather during summer months or 
low solar energy contribution in 
winter months may mean you will 
need to activate the gas boosting 
more often (refer to 
 on 
 
 
• 
Pilot flame alight? 
Check the pilot flame is burning by 
removing the access cover. Relight 
the pilot flame according to the 
lighting instructions (refer to 
 on 
• 
Gas burner not operating 
Inspect the isolating switch (adjacent to the water heater or at the switch 
board marked “HOT WATER” or “WATER HEATER”) and ensure it is turned 
“ON”. 
 
Note: Check the settings on the TIMER are sufficient to allow a full boosting 
cycle (2½ hours, from 4:00 PM to 6:30 PM, is recommended). 
• 
Collectors shaded 
If trees or other objects shade the solar collectors or if the glass is dirty, the 
effectiveness of the solar collectors will be greatly reduced. Have the trees 
trimmed or the solar collectors relocated if the obstruction is permanent or 
clean the collector glass (refer to 
• 
Collector area is too small 
For most installations, the number of solar collectors recommended in 
Rheem literature has been proven to provide the required solar energy to 
meet the average family needs. However, in some circumstances, it may be 
necessary to install an additional solar collector. 