INSTALLATION – SOLAR COLLECTORS 
 
SOLAR COLLECTOR LOCATION 
Consideration must be given to the position of the solar collectors in relation to 
the solar storage tank. There are limitations on the maximum length of the solar 
hot and solar cold pipes between the solar storage tank and the solar 
collectors. Refer to 
• 
The solar collectors must be installed in a shade free position. 
• 
The solar collectors are to be installed 
facing toward the equator (i.e. north 
facing in the southern hemisphere and 
south facing in the northern 
hemisphere). Where this orientation is 
not practical, a system facing up to 45
° 
from the equator will have its efficiency 
reduced by approximately 4%. 
 
 
 
• 
Inclination of the solar collectors should 
be approximately equal to 90% of the 
local latitude angle. The 
page 37. Solar collectors may be 
installed at the roof angle for simplicity 
of installation and appearance, but must 
never be flat. If the roof angle varies by 
15
° from the correct angle, efficiency 
will be reduced by 10%. 
• 
For an installation on a roof with a pitch less than 10
°, a Variable Pitch 
stand is required. Refer to your local Solar Distributor for details. 
• 
For an installation at right angles to (across) the roof pitch, a Flat Roof stand 
and an Across Pitch kit are both required. Refer to your local Solar 
Distributor for details. 
• 
For an installation opposite to (against) the roof pitch, a Flat Roof stand and 
an Against Pitch kit are both required. Refer to your local Solar Distributor 
for details. 
• 
The collector kit is suitable for installations with an inclination of up to 30
°. 
Where the solar collectors are installed at inclinations greater than 30
°, a 
With Pitch frame is necessary. Refer to your local Solar Distributor for 
details. 
• 
The roof must be suitable to take the mass of the solar collectors. Each 
solar collector and its fittings weighs approximately 40 kg when full of water. 
36