LIGHTING THE WATER HEATER 
49 
LIGHTING INSTRUCTIONS 
Using the gas control light the water heater as follows: 
1.  Stop, read the 
2.  Turn the gas control knob fully clockwise to the “z” (off) position. 
3.  Wait five (5) minutes so any build up of unburnt gas can escape. If you 
then smell gas, stop and follow “C” in the safety information. If you do not 
smell gas, proceed to step 4. 
4.  Turn the knob to the “·” (pilot) position. 
5.  Depress the knob fully (until star disappears below housing) and after 
30 seconds, whilst keeping the knob depressed, repeatedly press the 
igniter button (for up to 40 seconds) until the pilot flame ignites. 
 Warning: Keep your face clear of the combustion chamber opening 
while pressing the igniter. 
Note: It is not possible to depress the knob fully if the gas control has 
activated its safety shut-off feature. In this case, wait 60 seconds for the 
gas control to reset. 
6.  Keep the knob depressed for 20 seconds after the pilot flame lights. The 
pilot can be checked by looking through the large opening below the gas 
control. 
7.  Release the knob and check the pilot is still alight. 
8.  If the pilot has failed to light or has not remained alight, turn the gas control 
knob to the "z” (off) position. Wait five (5) minutes for any unburnt gas to 
escape and then begin again at step 3. 
 Warning: Failure to wait five (5) minutes may result in a fire or 
explosion. 
9.  When the pilot flame remains alight with the gas control knob released, 
turn the knob counter-clockwise to the setting of "6". This will give a water 
temperature of about 60°C. 
Rheem recommends the thermostat is set at 60
°C to maximise solar 
contribution. 
10.  Refer to “Temperature Adjustment” on page 5, if further adjustment is 
required. 
11.  Replace the access cover.