Справочник Пользователя для Rheem GAS BOOSTED SOLAR WATER HEATER

Скачать
Страница из 56
 
29 
CONNECTIONS – PLUMBING 
 
CONNECTION SIZES 
•  Hot water connection: RP¾/20. 
•  Cold water connection: RP¾/20. 
•  Tempered water connection: RP¾/20 
•  Solar hot (from collector) connection: DN15 compression fitting. 
•  Solar cold (to collector) connection: DN15 compression fitting. 
•  Temperature Pressure Relief valve connection: RP½/15. 
•  Gas connection: R¾/20. 
 
All plumbing work must be carried out by a qualified person and in accordance with the National 
Plumbing Standard AS/NZS 3500.4 and local authority requirements. 
 
All gas work must be carried out by a qualified person and in accordance with the Australian Gas 
Installations Standard AS 5601 and local authority requirements. 
 
It is necessary to remove the pipe cover from underneath the gas booster, by undoing the retaining 
screws, in order to make the water and gas connections to the water heater. Refit the pipe cover at the 
completion of the installation. 
 
WATER INLET AND OUTLETS 
All pipe work must be cleared of foreign matter before 
connection and purged before attempting to operate the 
water heater. All olive compression fittings must use 
brass or copper olives. Use thread sealing tape or 
approved thread sealant on all fittings.  
 
An isolation valve and non return valve must be 
installed on the cold water line to the water heater. Use 
the arrangement shown in the diagram. Refer also to 
21. The plumbing 
arrangements for the cold water inlet, tempered water 
and hot water outlets are shown on page 29. The solar 
hot and solar cold pipe connections are shown on 
page 32. 
 
A disconnection union must always be provided at the 
cold water inlet, tempered water and hot water outlets 
on the water heater to allow for disconnection of the 
water heater. It is necessary to remove the brass plug 
from the hot water outlet fitting if a hot water line is to 
be installed. This plug can be used to plug the 
tempered water outlet if a tempered water line is not 
being installed. Refer to the diagram for the connection 
points to the water heater. 
 
Insulation used on the tempered water and hot water 
lines must extend up to the outlets of the water heater. 
The valve and fittings must also be insulated up to the 
hot water outlet of the gas booster. 
 
 
 
 
 
cold water 
inlet 
tempered 
water outlet 
hot water 
outlet