Листовка для Rheem Guardian PowerVent

Скачать
Страница из 2
VENTING INFORMATION FOR 2" VENTS
CROSS REFERENCE AND SPECIFICATIONS
Residential water heaters
from Rheem
Rheem Water Heating • 101 Bell Road, Montgomery, AL 36117-4305
800-621-5622 • sales@rheem.com • www.rheem.com
Rheem Canada Ltd./Ltée • Water Heater Division
128 Barton Street West, Hamilton, Ontario L8N 3P3
Not all models are available in Canada.
Printed in U.S.A.
05/07 WP
Form No. 101-65 Rev. 3
RHEEM INDUCED DRAFT GAS POWERVENT
Guardian System
Air / fuel shut-off
system offers
double protection
Maintenance free –
no filter to clean
Flammable Vapor
Detection Sensor
Protective control system that
disables the heater in the
presence of flammable vapor
accumulation
Flexible Venting Options
Long venting lengths up to 100 feet
PVC, ABS, or CPVC vent pipe options
Vertical or horizontal termination
New Quiet Blower
Less noise than ever before
Self-Diagnostic System
Integrated self-diagnostic
system control takes the
guess work away
Environmentally
Friendly Burner
Low NOx design for low
nitrous oxide emissions
High Altitude Compliant
Tall models are certified for applications up to
7,700 feet above sea level
Short models: certified up to 6,000 feet above
sea level
Self-Cleaning
EverKleen
patented system fights sediment
build-up
Reduces fuel costs
Provides more hot water
Longer Life
Patented magnesium anode rod design
incorporates a special resistor that protects
the tank from corrosion.
Provides longer
tank life than using
standard magnesium
anode rods
HOT
WATER
CONNECTION
COLD
WATER
CONNECTION
POWER VENT
ASSEMBLY
C
B
F
A
D
G
G
E
T&P FITTING
3/4" N.P.T.
1/2"
Energy Factor and
Average Annual
Operating Costs based
on D.O.E. (Department
of Energy) test proce-
dures. D.O.E. national
average fuel rate
natural gas 91¢/therm;
LP $1.23/gallon.
6-Year Limited Tank
and Parts Warranty
See Residential Warranty
Information Brochure for
complete warranty information.
DESCRIPTION
FEATURES
ROUGHING IN DIMENSIONS (SHOWN IN INCHES)
ENERGY INFO.
NEW
HT. TO
HT. TO
WATER
HT. TO
WATER
PREVIOUS
FVIR
GAS INPUT IN
RECOVERY IN
FIRST HOUR
TOP OF
TANK
GAS
CONN.
SIDE T&P
CONN.
SHIP.
ENERGY
AVG. ANN.
GAL.
MODEL
MODEL
THOUS. BTU/HR.
G.P.H. 90° RISE
DEL. G.P.H.
ASSEMBLY
HT.
DIAM.
CONN.
CNTR.
VALVE
SIZE
WT.
FACTOR
OPER. COSTS
CAP.
NUMBER
NUMBER
NAT.
LP
NAT.
LP
NAT.
A
B
C
D
E
F
G
(LBS)
NAT.
NAT. GAS
40
41VRP40
42VP40F
40
40
40.4
40.4
68
69-1/4
59
19-3/4
14
8
53-1/2
3/4
140
0.64
$213
50
41VRP50
42VP50F
42
42
42.4
42.4
87
68-1/4
58
21-3/4
14
8
52-1/2
3/4
170
0.64
$213
40
NEW!
42VP40SF
36
34
36.4
34.3
71
61-1/2
50-1/2
20-1/4
14
8
44
3/4
152
0.64
$213
50
NEW!
42VP50SF
36
34
36.4
34.3
85
61-1/2
50-1/2
22-1/4
14
8
44
3/4
176
0.62
$220
T
Y
P
E
TALL
SHORT
NUMBER OF
MINIMUM
MAXIMUM
90° ELBOWS
NUMBER
PIPE
PIPE
WITH VENT
OF 45°
LENGTH
LENGTH
TERMINAL
ELBOWS
REQ. (FT.)
(FT.)
One (1)
None
4.0
44.0
One (1)
One (1)
4.0
41.0
Two (2)
None
4.0
38.0
Two (2)
One (1)
4.0
35.0
Three (3)
None
4.0
32.0
For the 2" vent, one 90° elbow is approximately equal to 6 feet of
pipe. One 45° elbow is approximately equal to 3 feet of pipe.
VENTING INFORMATION FOR 3" VENTS
NUMBER OF
MINIMUM
MAXIMUM
90° ELBOWS
NUMBER
PIPE
PIPE
WITH VENT
OF 45°
LENGTH
LENGTH
TERMINAL
ELBOWS
REQ. (FT.)
(FT.)
One (1)
None
5.0
95.0
One (1)
One (1)
5.0
92.5
Two (2)
None
5.0
90.0
Two (2)
One (1)
5.0
87.5
Three (3)
None
5.0
85.0
Three (3)
One (1)
5.0
82.5
Four (4)
None
5.0
80.0
Four (4)
One (1)
5.0
77.5
Five (5)
None
5.0
75.0
For the 3" vent, one 90° elbow is approximately equal to 5 feet of
pipe. One 45° elbow is approximately equal to 2.5 feet of pipe.
In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.