These conditions may result in either water at a temperature exceeding the 
requirements of AS/NZS 3500.4 being delivered to the hot water outlets in the 
ablution areas, or the device closing completely and not delivering water at all, 
or the device failing. Under either condition, the operation and performance of 
the device cannot be guaranteed. 
 
 
 
Circulated Hot Water Flow and Return System – Gas Water Heater 
 
REDUCING HEAT LOSSES 
The cold water line to and the hot water line from the water heater must be 
insulated in accordance with the requirements of AS/NZS 3500.4. The 
insulation must be weatherproof and UV resistant if exposed. 
 
Keep temperature settings down. Lower temperatures reduce heat losses and 
prolong cylinder life. Do not set the controlling electronic thermostat above 
70°C unless it is necessary. A time clock to control the electrical supply can be 
used to switch off the water heater during hours or days when it is not in use. 
 
ANODE TYPES 
The correct anode type for the water supply being used must be fitted in the 
water heater (refer to 
“Water Supplies”
 on page 46). The black anode is fitted 
as standard. 
 
Total Dissolved Solids in water supply to the water heater 
Anode colour code 
0-40 mg/L 
Green 
40-600 mg/L 
Black 
600-2500 mg/L 
Blue