LIGHTING THE WATER HEATER 
40 
DIAGNOSTIC FEATURES OF HOT SURFACE IGNITION CONTROL 
Warning:
 The removal of the access covers will expose 240 V wiring. They 
must only be removed by an authorised or service person only. 
 
The water heater incorporates an electronic control module. This is located 
inside the access cover of an indoor model and to the right of the access cover 
inside the air duct on an outdoor model (refer to 
pages 
22 and 23). 
 
An LED light on the module will flash once when power is switched on to the 
water heater. In the event of a fault occurring in or affecting the Hot Surface 
Ignition system, the system will enter “lock out” and the LED will emit a series 
of flashes diagnosing the fault. There will be a 2 second interval between each 
group of flashes. 
 
 
Flashes Fault 
Re-ignition attempt lockout. 
631 275 models only – Pressure switch not open. 
631 275 models only – Pressure switch not closed. 
4 Faulty 
igniter/igniter sensing circuit. 
Flame sensed with gas valve de-energized. 
Active and neutral wiring reversed. 
Check flame sensor and/or appliance grounding. 
Rapid 
Frequency check failure. 
Remains 
on 
Press the reset button.* 
 
* Note:
 If the LED light remains on after pressing the 
reset button, the electronic control must be replaced. 
Phone your nearest Rheem Service Department or 
Accredited Service Agent. 
 
 
TEST THE WATER HEATER AFTER INSTALLATION 
• 
The operation of the water heater must be thoroughly checked by the 
installer. 
• 
The burner flame must light smoothly and quickly from the hot surface 
igniter and must go out quietly and completely. 
• 
The burner flame must be stable, although slight lifting at the front edge of 
the burner is acceptable when the burner is cold. 
reset button 
 
LED 
indicator light