Листовка для Rheem GT-199XN-1

Скачать
Страница из 2
Temp. Rise (°F)
35
45
50
60
70
77
90
100
110
120
130
140
Water Flow (GPM)
8.5
7.4
6.6
5.5
4.7
4.3
4.1
3.7
3.3
2.8
2.6
2.4
MAXIMUM HOT WATER FLOW RATE AND TEMPERATURE RISE
CLEARANCE TO 
COMBUSTIBLES 
(inches)
MODEL
NUMBER
SIDE REAR
GT-199PV 1/2
0
12
GT-199X
1/2
0
12
Rheem-Ruud Heavy-Duty Tankless continued.
MODEL
GAS INPUT
CONNECTIONS
APPROXIMATE
NUMBER
BTU/HR
A
B
C
DEPTH
VENT*
WATER
GAS
SHIPPING  WEIGHT
GT-199PV
19,000-199,900
25-3/8
14-7/8
28-3/4
11-1/8
4
3/4
3/4
55 lbs.
GT-199X
19,000-199,900
25-3/8
14-7/8
22
11-1/8
N/A
3/4
3/4
55 lbs.
GT-199DV
19,000-199,900
25-3/8
14-7/8
28-3/4
11-1/8
4 by 4
3/4
3/4
55 lbs.
2-PIPE
DIMENSIONS 
(Inches)
Minimum flow rate required to initiate heating cycle .66 gpm.
Above estimates are for sizing purposes only.
A
C
REMOTE
CONTROL
B
POWER
F
A
B
REMOTE
CONTROL
POWER
F
C
FRONT
TOP &
BOTTOM
RHEEM-RUUD GT-199 MANIFOLD INSTALLATIONS
TEMP.
FLOW RATE (GPM)
RISE (°F)
1 UNIT
2 UNITS
5 UNITS
10 UNITS
15 UNITS
20 UNITS
140
2.4
4.8
12.0
24.0
36.0
48.0
130
2.6
5.2
13.0
26.0
39.0
52.0
120
2.8
5.6
14.0
28.0
42.0
56.0
110
3.0
6.0
15.0
30.0
45.0
60.0
100
3.3
6.6
16.5
33.0
49.5
66.0
90
3.7
7.4
18.5
37.5
55.5
74.0
80
4.2
8.4
21.0
42.0
63.0
84.0
70
4.8
9.6
24.0
48.0
72.0
96.0
60
5.6
11.2
28.0
56.0
84.0
112.0
50
6.7
13.4
33.5
67.0
100.5
134.0
45
7.4
14.8
37.0
74.0
111.0
148.0
35
8.5
17.0
42.5
85.0
127.5
170.0
# OF WATER HEATERS
2
3 TO 6
7 TO 20
PART NO.
DESCRIPTION
ACCESSORIES
RTG20040
EZ-Link
Cable
1
N/A
N/A
MIC-180
Main Communication N/A
1
1
PCB w/ Manifold 
Control Box
MICS-180
Extended N/A
N/A
1
Communications 
PCB
MIC-K-16
Communications 
N/A
3 to 6
7 to 20
Cable (16 ft.)
MIC-K-32
Communications 
N/A
3 to 6
7 to 20
Cable (32 ft.)
MIC-K-65
Communications 
N/A
3 to 6
7 to 20
Cable (65 ft.)
ACCESSORIES FOR MULTI-UNIT MANIFOLD INSTALLATIONS
GT-199PV (Indoor)
GT-199X (Outdoor)
A
B
REMOTE
CONTROL
POWER
F
C
GT-199DV (Indoor)
• Specify natural or LP gas when ordering.
• Electrical rating: 120V, 60HZ, less than 2 amps. Indoor model supplied with 120 volt power cord.
* Category III stainless steel (UL1738 certified) vent is required.
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama 36117-4305 • www.rheem.com
P R I N T E D   I N   U . S . A
1 2 / 0 6   W P
F O R M   N O . 1 0 1 - 2 4   R e v. 2
In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice.
Indoor and Direct Vent Models Vent Horizontally or Vertically
These water heaters have a built-in electric blower to force exhaust gas to the outside. Category
III stainless steel vent is (UL1738 certified) required in order to avoid damage from possible
condensation. Maximum vent length for GT-199 models is 47 feet 6 inches including one 90°
elbow. Maximum vent length for GT-199DV models is 47 feet 6 inches including two 90° elbows.
Type “B” vents are not permitted.
Indoor Models
Direct Vent Models
GT-199DV standard
termination
venting 
side wall
GT-199DV sweet
termination
venting side wall
(Coming Soon!)
Venting side wall 
from side
Venting side wall 
from back
Required Direct Vent Termination Kits
Kits include the termination components only, vent pipe
from the heater to the termination is not included.
Horizontal and Vertical kits for Heat Fab and Protech 
are available.
DIRECT VENT KITS
Model
Termination
Heat Fab
Protech
GT-199DV
Horizontal
RTG-20032HHT
RTG20034HPT
GT-199DV
Vertical
RTG20033VHT
RTG20035VPT
GT-199DV Sweet
RTG20058
N/A
For 5"-9" Wall Thickness
RTG20059
For 9"-13" Wall Thickness
RTG20060
For 13"-17" Wall Thickness