Справочник Пользователя для Rheem 100

Скачать
Страница из 4
DIMENSIONAL INFORMATION
All dimensions shown in English and Metric
MODEL
WATER CONNECTIONS
APPROX
NUMBER
UNITS
A
B
C
D
E
F
G
H
VENT
INLET
OUTLET
SHIPPING WT.
inches
42
23 1/2
32
35
5
25 1/4
27 9/16
5 7/8
2
1
1
175 lbs.
mm
1067
597
813
889
127
641
700
149
51
25
25
79 kgs
inches
42
23 1/2
32
35
5
25 1/4
27 9/16
5 7/8
3
1
1
175 lbs.
mm
1067
597
813
889
127
641
700
149
76
25
25
79 kgs
inches
72
23 1/2
32
65
5
25 1/4
20 1/4
7 3/4
3*
1-1/2
1-1/2
235 lbs.
mm
1854
597
813
1651
127
641
514
197
76
38
38
106 kgs
inches
73
27
36
66 3/4
6 3/4
28 7/8
22
9 1/2
3*
1-1/2
1-1/2
405 lbs.
mm
1854
686
914
1695
171
733
559
241
76
38
38
184 kgs
* 130,000 BTU models are certified to be installed with 2" venting.
All models require a 120V power source.
See use and care manual for venting details.
HE45-100
HE45-130
HE45-160
HE45-199
HE80-130
HE80-160
HE80-199
HE119-130
HE119-160
HE119-199
0" CLEARANCE TO
COMBUSTIBLES ON
ALL ADVANTAGE
PLUS UNITS,
HOWEVER, A 24"
CONTROL PANEL
SERVICE
CLEARANCE IS
RECOMMENDED.
MODELS WITH
INPUTS OF 
100,000 BTU AND
130,000 BTU ARE
CERTIFIED TO VENT
WITH 2" SCHEDULE
40 PVC, CPVC OR
ABS PIPE
HE45-100
HE45-130
HE80-130
HE119-130
HE80-160
HE119-160
HE80-199
HE119-199
HE45-160
HE45-199
MAXIMUM DELIVERY
In U.S. Gallons and Liters 
(Includes useable storage and recovery for indicated times)
MODEL
INPUT (BTU/HR) TEMP.
5
10
15
20
30
45
1
2
3
MIN. TO RECOVER
NUMBER
GALLONS
LITERS
NAT. & LP
RISE
UNITS
MIN.
MIN.
MIN.
MIN.
MIN.
MIN.
HR.
HR.
HR.
CONTENTS
HE45-100
45
170
100,000
100°F
GAL.
41
51
60
70
89
118
147
262
377
23
37.7°C
LTR.
156
192
228
265
337
446
555
991
1427
HE45-130
45
170
130,000
100°F
GAL.
44
56
69
81
106
144
181
331
481
18
37.7°C
LTR.
166
214
261
308
403
544
686
1253
1819
HE80-130
80
303
130,000
100°F
GAL.
68
81
93
106
131
168
206
355
505
32
37.7°C
LTR.
259
306
354
401
495
637
779
1345
1912
HE119-130
119
450
130,000
100°F
GAL.
96
108
121
133
158
196
233
383
532
48
37.7°C
LTR.
363
410
457
504
599
750
882
1449
2015
HE45-160
45
170
160,000
100°F
GAL.
47
62
78
93
124
170
216
400
584
15
37.7°C
LTR.
177
235
294
352
468
642
817
1514
2211
HE80-160
80
303
160,000
100°F
GAL.
71
87
102
117
148
194
240
424
609
26
37.7°C
LTR.
270
328
386
444
561
735
909
1607
2304
HE119-160
119
450
160,000
100°F
GAL.
99
114
129
145
175
221
268
452
636
39
37.7°C
LTR.
373
432
490
548
664
838
1013
1710
2408
HE45-199
45
170
199,000
100°F
GAL.
51
70
89
108
146
203
261
490
719
12
37.7°C
LTR.
192
264
336
408
553
770
987
1854
2721
HE80-199
80
303
199,000
100°F
GAL.
75
94
113
132
171
228
285
514
743
21
37.7°C
LTR.
284
357
429
501
646
863
1079
1947
2814
HE119-199
119
450
199,000
100°F
GAL.
102
121
141
160
198
255
312
542
771
31
37.7°C
LTR.
338
460
532
604
749
966
1183
2050
2918
All models have a maximum setpoint of 160°F with the exception of the HE45-160 and HE45-199 booster models. The HE45-160 and HE45-199 have a maximum setpoint of 180°F.
RECOVERY CAPACITIES
Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises
MODEL
INPUT (BTU/HR)
THERMAL
40°F
50°F
60°F
70°F
80°F
90°F
100°F
110°F
120°F
130°F
140°F
NUMBER
NAT. & LP
EFFICIENCY
UNITS
(22°C)
(28°C)
(33°C)
(39°C)
(45°C)
(50°C)
(56°C)
(61°C)
(67°C)
(72°C)
(78°C)
100,000
95%
GPH
288
230
192
165
144
128
115
105
96
N/A
N/A
LPH
1090
872
726
623
545
484
436
396
363
N/A
N/A
130,000
95%
GPH
374
299
249
214
187
166
150
136
125
N/A
N/A
LPH
1417
1133
944
809
708
630
567
515
472
N/A
N/A
160,000
95%
GPH
461
368
307
263
230
205
184
167
154
N/A
N/A
LPH
1744
1395
1162
996
872
775
697
634
581
N/A
N/A
199,000
95%
GPH
573
458
382
327
286
255
229
208
191
N/A
N/A
LPH
2169
1735
1446
1239
1084
964
867
789
723
N/A
N/A
BOOSTER MODELS
160,000
95%
GPH
461
368
307
263
230
205
184
167
154
142
132
LPH
1744
1395
1162
996
872
775
697
634
581
536
498
199,000
95%
GPH
573
458
382
327
286
255
229
208
191
176
164
LPH
2169
1735
1446
1239
1084
964
867
789
723
667
620
Recovery rating is based on thermal efficiencies obtained in an UL certified laboratory.
AdvantagePlus Gas continued.