INSTALLATION 
17 
REDUCING HEAT LOSSES 
The cold water line to and the hot water line from the water heater must be 
insulated in accordance with the requirements of AS/NZS 
3500.4. The 
insulation must be weatherproof and UV resistant if exposed. 
 
ANODE TYPES 
The correct anode type for the water supply being used must be fitted in the 
water heater (refer to 
“Water Supplies”
 on page 30). The black anode is fitted 
as standard. 
 
Total Dissolved Solids in water supply to the water heater 
Anode colour code 
0 – 40 mg/L 
Green 
40 – 600 mg/L 
Black 
600 – 2500 mg/L 
Blue 
 
SADDLING - PIPE WORK 
To prevent damage to the cylinder when attaching pipe clips or saddles to the 
water heater jacket, we recommend the use of self-drilling screws with a 
maximum length of 12 mm. Should pre drilling be required, extreme caution 
must be observed when penetrating the jacket of the water heater. 
 
Note: Damage to the cylinder as a result of saddling to the jacket will void 
the warranty.