1.  Turn “OFF” the electric power supply to the water heater.
2.  Remove the outer door. Remove or fold up the insulation pad.
3.  A. 
Models with lower thermostat without high limit: Lift
 
out the tab as shown below to unclip the terminal cover
 
from the thermostat. The terminal cover can now be
 
removed from the thermostat.
          
FIGURE  10.
   B. 
Models with Upper or Lower Thermostat with High 
  
Limit: Lift  out  the  tab  as  shown  below  to  unclip  the
 
 
terminal   cover from the thermostat. The terminal cover  
 
can now be removed from the thermostat.
                      
FIGURE  11.
4.  Disconnect wires from thermostat and slide out of the bracket.
5.  Remove the thermostat from behind the thermostat bracket.
 
6.  Place the new lower thermostat in the bracket making sure it fi ts 
fi rmly against the tank.
7.  Attach the wires to the new thermostat.
 
NOTE: Some of the terminals may require straight-in wiring 
through an eye-opening. If wires are now looped, recut and 
strip wire 3/8” (9.525 mm) to a straight length and insert.
8.  Put plastic terminal cover back in place.
9.  Replace the insulation to cover the thermostat.
10. Replace outer door then turn the electric power on.
ELEMENT CLEANING / REPLACEMENT
NOTE: These instructions are written for element cleaning and 
element replacement for the lower element.
To remove the element from the tank in order to clean or replace 
it:
1.  Before beginning turn “OFF” the electric power supply to the 
water heater.
2.  Turn off the water supply to the water heater at the water shut-off 
valve or water meter, see Figure 12.
                        
FIGURE  12.
3.  Attach a hose to the water heater drain valve and put the other 
end in a fl oor drain or outdoors. Open the water heater drain valve. 
Open a nearby hot water faucet which will relieve pressure in the 
water heater and speed draining. 
                     