SPACE HEATING AND POTABLE WATER SYSTEM
Your water heater is equipped with inlet/outlet connections for use 
in space heating applications (see Figure 9). If this water heater 
is to be used to supply both space heating and potable (drinking) 
water, the instructions listed below must be followed:
•  Be sure to follow the manual(s) shipped with the air handler or 
other type heating system.
•  This water heater cannot be used in space heating applications 
only.
•  This  water  heater  is  not  to  be  used  as  a  replacement  for  an 
existing boiler installation.
•  Do not use with piping that has been treated with chromates, 
boiler seal or other chemicals and do not add any chemicals to 
the water heater piping
•  If the space heating system requires water temperatures in excess 
of 120°F, a mixing valve must be installed per the manufacturer’s 
instructions in the potable hot water supply to limit the risk of scald 
injury.
•  Pumps,  valves,  piping  and  fittings  must  be  compatible  with 
potable water.
•  A  properly  installed  flow  control  valve  is  required  to  prevent 
thermosiphoning. Thermosiphoning is the result of a continuous 
flow of water through the air handler circuit during the off cycle. 
Weeping (blow off) of the temperature and pressure relief valve 
(T & P relief valve) or higher than normal water temperatures are 
the first signs of thermosiphoning.
•  The hot water line from the water heater should be vertical past 
any mixing valve or supply line to the heating system to remove 
air bubbles from the system Do not connect the water heater to 
any  system  or  components  previously  used  with  non-potable 
water heating appliances when used to supply potable water.
•  These water heaters cannot be used in space heating applications 
only.
Figure: 9
CLOSED WATER SYSTEMS
Water supply systems may, because of code requirements or such 
conditions  as  high  line  pressure,  among  others,  have  installed 
devices such as pressure reducing valves, check valves, and back 
flow preventers. Devices such as these cause the water system to 
be a closed system.
THERMAL EXPANSION
As  water  is  heated,  it  expands  (thermal  expansion).  In  a  closed 
system  the  volume  of  water  will  grow  when  it  is  heated. As  the 
volume of water grows there will be a corresponding increase in 
water pressure due to thermal expansion. Thermal expansion can 
cause premature tank failure (leakage). This type of failure is not 
covered under the limited warranty. Thermal expansion can also 
cause  intermittent  temperature-pressure  relief  valve  operation: 
water discharged from the valve due to excessive pressure build 
up. This condition is not covered under the limited warranty. The 
temperature-pressure relief valve is not intended for the constant 
relief of thermal expansion.
A properly sized thermal expansion tank should be installed on all 
closed systems to control the harmful effects of thermal expansion. 
Contact  a  local  plumbing  service  agency  to  have  a  thermal 
expansion tank installed.
NOTE:  To  protect  against  untimely  corrosion  of  hot  and  cold 
water fittings, it is strongly recommended that di-electric unions 
or couplings be installed on this water heater when connected 
to copper pipe, see Figure 10 also.
Figure: 10
Figure 9 and Figure 10 show the typical attachment of the water 
piping to the water heater. The water heater is equipped with 3/4 
inch NPT water connections for 50 gallon unit and 1 inch NPT 
water connections for 75 gallon unit..
NOTE: If using copper tubing, solder tubing to an adapter before 
attaching the adapter to the water heater connections. Do not 
solder the water lines directly to the water heater connections. 
It will harm the dip tube and damage the tank, T & P Valve and 
Pipe Insulation (if supplied
)
Fit pipe insulation over the incoming cold water line and the hot 
water line. Make sure that the insulation is against the top cover of 
the heater.Fit T & P valve insulation over valve. Make sure that the 
insulation does not interfere with the lever of the T & P valve.
Secure all insulation using tape.