terMInatIon clearances sIdewall power vent
V
X
VENT TERMINAL
AIR SUPPLY INLET
AREA WHERE TERMINAL IS NOT PERMITTED
v
v
A
G
V
FIXED
CLOSED
FIXED
CLOSED
OPERABLE
OPERABLE
V
C
B
B
B
B
F
B
V
V
A
J
V
H
M
X
X
V
V
K
B
E
D
L
POWER VENT
(using room air for combustion)
EXTERIOR CLEARANCES FOR SIDEWALL VENT TERMINATION
fIGure 13
Vent terminal clearances for “Power Vent” installations. Power Vent configurations use room air for combustion.
us InstallatIons 1
us InstallatIons 1
a
Clearance above grade, 
veranda, porch, deck or 
balcony
12 inches (30 cm)
h
Clearance to each side 
of center line extended 
above meter/regulator  
assembly
3 feet (91 cm) within a 
height 15 feet (4.5 m) 
above the meter/regulator 
assembly*
b
Clearance to window 
or door that may be 
opened
4 feet (1.2 m) below 
or to side of opening; 
1 foot (30 cm) above 
opening
I
Clearance to service 
regulator vent outlet 
          
3 feet (91 cm)*
c
Clearance to 
permanently closed 
window
12 inches (30 cm)*
j
Clearance to a non 
mechanical air supply 
inlet into building or 
combustion air inlet to 
any other appliance
4 feet (1.2 m) below or to 
side of opening; 1 foot  
(30 cm) above opening.
d
Vertical clearance to 
ventilated soffit located 
above the terminal 
within a horizontal 
distance of 2 feet (61 
cm) from the center line 
of the terminal
12 inches (30 cm)*
K
Clearance to a 
mechanical air supply 
inlet
3 feet (91 cm) above if 
within 
10 feet (3 m) horizontally
e
Clearance to 
unventilated soffit
12 inches (30 cm)*
l
Clearance above paved 
sidewalk or paved 
driveway located on 
public property
7 feet  (2.13 m)
f
Clearance to outside 
corner
2 feet (60 cm)*
M
Clearance under 
veranda, porch, deck, or 
balcony
12 inches (30 cm) ‡
G
Clearance to inside 
corner
18 inches (45 cm)*
1 In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.
† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
* Clearance in accordance with local installation codes and the requirements of the gas supplier and the manufacturer’s installation instructions.