Справочник Пользователя для American Water Heater VG6250T100

Скачать
Страница из 60
36
for the lowest temperature which satisfies your hot water needs. 
This will also provide the most energy efficient operation of the 
water heater and minimize scale formation.
Valves for reducing the point-of-use temperature by mixing cold 
and  hot  water  are  available,  see  Figure  8. Also  available  are 
inexpensive  devices  that  attach  to  faucets  to  limit  hot  water 
temperatures. Contact a licensed plumber or the local plumbing 
authority.
The table below shows the approximate time-to-burn relationship for 
normal adult skin. Short repeated heating cycles caused by small 
hot water uses can cause temperatures at the point of use to exceed 
the thermostat setting by up to 20°F/11°C. If you experience this 
type of use, you should consider using lower temperature settings 
to reduce scald hazards.
table 8
Water Temperature
Time to Produce 
2nd & 3rd Degree 
Burns on Adult Skin
160° (71°C)
About 1/2 Second
150° (65°C)
About 1 1/2 Seconds
140° (60°C)
Less than 5 Seconds
130° (54°C)
More than 30 Seconds
120° (49°C)
More than 5 Minutes
hI lIMIt swItch (eco)
This water heater is equipped with an ECO (energy cut out) non 
adjustable  high  temperature  limit  switch. The  ECO  is  a  normally 
closed switch that opens (activates) on a rise in temperature. The 
ECO  is  located  inside  the  Temperature  Probe  (two  red  wires). 
The  ECO  switch  contacts  will  open  when  the  water  temperature 
reaches  approximately  202°F  (94°C)  and  close  at  approximately 
140°F (49°C).
If  the  ECO  activates  (contacts  open)  due  to  abnormally  high 
water  temperatures  in  the  storage  tank  the  control  system  will 
immediately  de-energize  the  24  VAC  Gas  Valve  and  end  the 
current heating cycle. The control system will “lock out” disabling 
further  heating  operation.  The  control  system  will  display  the 
“Energy Cut Out (ECO)” Fault message on the LCD screen. It is 
important that a Qualified Service Agent be contacted to determine 
the reason for the ECO activation before resetting the ECO. Once 
the reason has been determined and corrected the ECO can be 
reset as follows:
Should the ECO activate, the water temperature must drop below 
140°F  (49°C)  before  the  control  system  can  be  reset.  Once  the 
water temperature has cooled below this point the power supply 
to the water heater must be turned off and on again to reset the 
control system.
Contact  your  dealer  or  servicer  if  continued  high  limit  switch 
operation occurs.
It is recommended that lower water temperatures be used to avoid 
the risk of scalding. It is further recommended, in all cases, that the 
water temperatures be set for the lowest temperature which satisfies 
your hot water needs. This will also provide the most energy efficient 
operation of the water heater.
HOT WATER CAN SCALD: Water heaters are intended to produce 
hot water. Water heated to a temperature which will satisfy space 
heating, clothes washing, dish washing, and other sanitizing needs 
can scald and permanently  injure you upon contact. Some people 
are more likely to be permanently injured by hot water than others. 
These include the elderly, children, the infirm, or physically/mentally 
handicapped. If anyone using hot water from this heater fits into 
one of these groups or if there is a local code or state law requiring 
a certain temperature water at the hot water tap, then you must 
take special precautions. In addition to using the lowest possible 
temperature setting that satisfies your hot water needs, a means 
such as a mixing valve, should be used at the hot water taps used 
by these people or at the water heater. Mixing valves are available 
at  plumbing  supply  or  hardware  stores,  see  Figure  8.  Follow 
manufacturer’s  instructions  for  installation  of  the  valves.  Before 
changing the factory setting on the thermostat, read the “Temperature 
Regulation” section in this manual.
Never allow small children to use a hot water tap, or to draw their own 
bath water. Never leave a child or handicapped person unattended 
in a bathtub or shower.
SETTING THE WATER HEATER TEMPERATURE AT 120°F/49°C 
WILL  REDUCE THE  RISK  OF  SCALDS.  Some  states  require 
settings at specific lower temperatures.
The  water  temperature  is  controlled  using  the  Temperature 
Control on the Display at the front of the unit (See Figure 1). 
This control utilizes a temperature probe to determine the tank 
temperature.  The  temperature  probe  is  located  behind  the 
heater’s front display.
The temperature may be adjusted from 90°F/32°C to 160°F/71.1°C. 
The temperature was preset to 120°F/49°C before the heater was 
shipped  from  the  factory.  It  is  recommended  that  lower  water 
temperature be used to avoid the risk of scalding. It is further 
recommended, in all cases, that the water temperature be set 
teMperature reGulatIon