precautIons
DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER 
WATER. Immediately call a qualified service agency to inspect the 
appliance  and  to  make  a  determination  on  what  steps  should  be 
taken next.
If the unit is exposed to the following, do not operate heater until all 
corrective steps have been made by a qualified service agency.
1.  External fire.
2. Damage.
3.  Firing without water.
GroundInG InstructIons
This water heater must be grounded in accordance with the National 
Electrical Code and/or local codes. These must be followed in all 
cases. Failure to ground this water heater properly may also cause 
erratic control system operation.
This  water  heater  must  be  connected  to  a  grounded  metal, 
permanent  wiring  system;  or  an  equipment  grounding  conductor 
must  be  run  with  the  circuit  conductors  and  connected  to  the 
equipment grounding terminal or lead on the water heater.
hYdroGen Gas flaMMable
Explosion Hazard
Flammable hydrogen gases
may be present.
Keep all ignition sources away
from faucet when turning on
hot water.
Hydrogen gas can be produced in a hot water system served by this 
appliance that has not been used for a long period of time (generally 
two  weeks  or  more).  Hydrogen  gas  is  extremely  flammable.  To 
reduce the risk of injury under these conditions, it is recommended 
that  a  hot  water  faucet  served  by  this  appliance  be  opened  for 
several  minutes  before  using  any  electrical  appliance  connected 
to the hot water system. If hydrogen is present there will probably 
be an unusual sound such as air escaping through the pipe as the 
water begins to flow. THERE SHOULD BE NO SMOkING OR OPEN 
FLAME NEAR THE FAUCET AT THE TIME IT IS OPEN. 
Read and understand this instruction
manual and the safety messages
herein before installing, operating or
servicing this water heater.
Failure to follow these instructions and
safety messages could result in death
or serious injury.
This manual must remain with the
water heater.
Water temperature over 125°F (52°C)
can cause severe burns instantly
resulting in severe injury or death.
Children, the elderly and the
physically or mentally disabled are at
highest risk for scald injury.
Feel water before bathing or
showering.
Temperature limiting devices such as
mixing valves must be installed
when required by codes and to
ensure safe temperatures at fixtures.
Explosion Hazard
Overheated water can cause
water tank explosion.
Properly sized temperature and
pressure relief valve must be
installed in the opening provided.
verify the power to the water heater is turned off before performing any service procedures.
Improper installation, use and service may result
in property damage.
Do not operate water heater if flood damaged.
Inspect and anode rods regularly, replace if damaged.
Install in location with drainage.
Fill tank with water before operation.
Properly sized thermal expansion tanks are required on all
closed water systems.
Refer to this manual for installation and service.
CAUTION
General safetY InforMatIon