17375-6-0705
               
Figure 39
Figure 41
See Horizontal Termination Page 24 and Vertical Termination 
Page 25-26.
FRAMING AND FINISHING (continued)
HORIZONTAL TERMINATION
NOTE:  Termination cap should pass through the wall firestop 
from the exterior of the building. Adjust the termination 
cap to its final exterior position on the building.
WARNING:  Termination  cap  must  be  positioned  so  that 
arrow is pointing up.
Attach the termination cap with the four wood screws provided. 
Before attachment of the termination, run a bead of silicone sealant 
rated above 250°F on its outside edge too, so as to make a seal 
to the exterior wall.
NOTE Wood screws can and should be replaced with appropriate 
fasteners for use on stucco, brick, concrete or other types 
of siding.
CAUTION: If exterior walls are finished with vinyl siding, (or 
materials that could become discolored or warp) it is necessary 
to install the vinyl siding standoff SD-1250.
Vinyl siding standoff SD-1250 will be installed between the vent 
termination and the exterior wall. (See Figure 42) This horizontal 
vent termination bolts onto the flat portion of the vinyl siding 
standoff,  so  an  air  space  will  exist  between  the  wall  and  the 
termination cap.
Figure 40
Figure 42