Rosemount Tank Radar REX
Chapter 14 Technical Data
14-10
Installation Manual
308014EN, Edition 4
May 2013
14.8 Field Communication Unit, FCU 2160
Ambient operating temperature
-40°C to +70°C (-40°F to +158°F)
Power Supply
115 or 230 VAC, +10% to -15%, 
50-60 Hz, max 10 W.
Group bus interface
TRL/2 Bus, RS 232 or RS 485.
Field bus interface
TRL/2 Bus. Max 8 units on one 
port.
Number of Group/Field buses
Individually configurable:
4+2
1)
 (Field bus/Group bus)
3+3 (Field bus/Group bus)
2+4 (Field bus/Group bus).
Hazardous locations certifications
None.
Number of tanks 
RTG and SDAU: Max 32 
(max 8 per field bus).
14.9 Field Bus Modem, FBM 2180
Power supply (for RS-232)
DC 7-12 V, 50 mA
Cable to Host PC
RS 232: 3 m (10 ft)
USB: 3 m (10 ft)
Hazardous locations certifications
None
Field bus over-voltage protection
Galvanic insulation, transient 
protection, suppressors
Field interface
TRL/2
Computer/Host interface
RS-232 or USB
LED indicators
External power, host connection, 
TRL/2 transmit and receive
14.10 Enraf Bus Modem, EBM
Power supply
8 to 14 VDC unregulated, 9 V 
typical. Maximum 300 mA @ 9 V 
input voltage.
Cable to PC
3 m (10 ft), RS 232, included in 
delivery.
Hazardous locations certifications
None.
1.Standard