Справочник Пользователя для Emerson 308014EN
2-3
Rosemount Tank Radar REX
Chapter 2 Safety
Installation Manual
308014EN, Edition 4
May 2013
May 2013
2.3
European ATEX Directive Information
2.3.1
Radar Unit
The REX Radar Unit has been certified to comply with Directive 94/9/EC
of the European Parliament and the Council as published in the Official
Journal of the European Communities No. L 100/1.
of the European Parliament and the Council as published in the Official
Journal of the European Communities No. L 100/1.
Figure 2-1. Certification label ATEX for the 2015 Radar Unit (used in
3900 series radar tank gauges).
The following information is provided as part of the label of the radar unit:
•
Name and address of the manufacturer
(Rosemount Tank Radar AB).
(Rosemount Tank Radar AB).
•
CE Conformity Marking
•
Complete model number
•
The serial number of the device
•
Year of construction
•
Marking for explosion protection:
•
Ex d IIB Gb T6 (-40 °C
Ta +70 °C)
•
Baseefa(2001) ATEX certificate number: Baseefa03ATEX0071X
Special Conditions for Safe Use (X):
•
The Type TH2015-2019 Radar Units are not to be mounted
directly on to a tank.
directly on to a tank.
•
For replacement purposes the cover fastening screws are to be of
minimum grade A4-80 stainless steel.
minimum grade A4-80 stainless steel.
•
The permanently attached cables are to be suitably terminated
and protected against impact.
and protected against impact.