SPECIFICATIONS
REPLACEMENT PARTS
Note:
 Use only original replacement parts. This 
will protect your warranty  coverage  for  parts 
replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers  of  this  product.  If 
they can’t supply original replacement part(s), 
call  DESA Technical  Service  Department  at 
1-866-672-6040.
When calling DESA, have ready
•  your name
•  your address
•  model and serial numbers of your heater
•  how heater was malfunctioning
•  type of gas used (propane/LP or natural gas)
•  purchase date
Usually, we will ask you to return the part to the 
factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product. If they 
can’t supply original replacement part(s), call DESA 
at 1-866-672-6040 for referral information.
When calling DESA, have ready
•  model and serial numbers of your heater 
•  the replacement part number
EQUIPMENT SHUTOFF VALVE 
GA5010
For all models. Equipment shutoff valve with 1/8" 
NPT tap. Fits 1/2" NPT pipe.
SERVICE HINTS
When Gas Pressure Is Too Low
•  pilot will not stay lit
•  burners will have delayed ignition
•  heater will not produce specified heat
•  propane/LP gas supply may be low
You may feel your gas pressure is too low. If so, con-
tact your local propane/LP or natural gas supplier.
ACCESSORIES
Purchase these heater accessories from your local 
dealer. If they can not supply these accessories, call 
DESA at 1-866-672-6040 for referral information. 
You can also write to the address listed on the back 
page of this manual.
VFRMV18NB
•  Rating (Variable): 20,000/30,000 Btu/Hr
•  Gas Type: Natural Gas Only
•  Ignition: Piezo
•  Manifold Pressure: 3.5" - 1.6" W.C.
•  Inlet Gas Pressure (in. of water):
  Maximum 10.5" W.C., Minimum* 5.0" W.C.
VFRMV18PB
•  Rating (Variable): 23,000/30,000 Btu/Hr
•  Gas Type: Propane/LP Only
•  Ignition: Piezo
•  Manifold Pressure: 10" - 6.3" W.C.
•  Inlet Gas Pressure (in. of water):
  Maximum 14" W.C., Minimum* 11" W.C.
VFRMV24NB
•  Rating (Variable): 24,000/36,000 Btu/Hr
•  Gas Type: Natural Gas Only
•  Ignition: Piezo
•  Manifold Pressure: 3.5" - 1.6" W.C.
•  Inlet Gas Pressure (in. of water):
  Maximum 10.5" W.C., Minimum* 5.0" W.C.
VFRMV24PB
•  Rating (Variable): 26,000/34,000 Btu/Hr
•  Gas Type: Propane/LP Only
•  Ignition: Piezo
•  Manifold Pressure: 10" - 6.3" W.C.
•  Inlet Gas Pressure (in. of water):
  Maximum 14" W.C., Minimum* 11" W.C.
* For purpose of input adjustment
Manufactured by: DESA, 1769 E. Lawrence St., Russellville, AL 35653
Note:
 This appliance has been designed-certified by ANS Z21.11.2b-2004 Unvented Room Heaters 
and ANS Z21.60-2003.
Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories.