PRODUCT 
IDENTIFICATION
Figure 1 - Product Identification
Log Set
Chassis Assembly
LOCAL CODES
Install and use the heater with care. Follow all 
local codes. In the absence of local codes, use the 
latest edition of the National Fuel Gas Code ANSI 
Z223.1/NFPA 54*
*Available from:
American National Standards Institute, Inc.
1430 Broadway
 New York, NY 10018
National Fire Protection Association, Inc.
Battery march park
Quincy, MA 02269
Note:
 Where listed vented decorative logs are 
required, thermostat operations is not permitted. 
The installation of appliances designed for manu-
factured home (U.S. only) or mobile home instal-
lation must conform with the Standard CAN/CSA 
Z240 MH, Standard, Title 24 CFR, Part 3280, in 
the United States or when such a Standard is not 
applicable, ANSI/NCSBCS A225.1/NFPA 501A 
Manufactured Home Installations Standard.
UNPACkING
 CAUTION: Do not remove the 
data  plates  from  the  grate  as-
sembly. The data plates contain 
important  warranty  and  safety 
information.
1.  Remove  log  set  assembly  from  carton. 
Note:
  Do  not  pick  up  assembly  by  logs. 
This could damage the unit. Always handle 
assembly by grate.
2.  Remove all protective packaging applied to 
log set for shipment.
3.  Check all items for any shipping damage. If 
damaged, promptly inform dealer where you 
bought appliance.
OPTIONAL REMOTE 
CONTROL ACCESSORIES
There are four optional remote controls that can 
be purchased separately:
Wall switch 
Hand-held ON/OFF remote
Wall thermostat  Hand-held thermostat remote
See Accessories, page 26.
The wall thermostat or hand-held thermostat may not 
be used where vented decorative listings is required.
PRODUCT FEATURES
OPERATION
This heater is clean burning. It requires no outside 
venting. There is no heat loss out a vent or up a 
chimney. Heat is generated by both realistic flames 
and glowing coals. This heater is designed for 
vent-free operation with flue damper closed. It 
has been tested and approved to ANSI Z21.11.2 
standard for unvented heaters. State and local 
codes in some areas prohibit the use of vent-free 
heaters. This heater may also be operated as a 
vented  decorative  (ANSI  Z21.60)  product  by 
opening the flue damper.
SAFETY DEVICE
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shut off system. The 
ODS/pilot is a required feature for vent-free room 
heaters. The ODS/pilot shuts off the heater if there 
is not enough fresh air.
PIEZO IGNITION SYSTEM
This heater has a piezo ignitor. This system re-
quires no matches, batteries or other sources to 
light heater.
State of Massachusetts: The installation 
must  be  made  by  a  licensed  plumber  or 
gas fitter in the Commonwealth of Mas-
sachusetts.
Sellers  of  unvented  propane  or  natural 
gas-fired supplemental room heaters shall 
provide to each purchaser a copy of 527 
CMR 30 upon sale of the unit.
Vent-free  gas  products  are  prohibited  for 
bedroom  and  bathroom  installation  in  the 
Commonwealth of Massachusetts.