8. ELECTRIC MECHANISM 
 
-10. Checking the input voltage 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
3620Q
[KE-436B, 436C]
3619Q 
1. Turn on the power switch. 
2. Press the SELECT switch (1) until the Y-SCALE indicator (2) illuminates. 
[KE-436B, 436C] 
Press the menu switch (1) until the X-SCALE indicator (2) illuminates. 
3. While pressing the TEST switch (3), press the RESET switch (4). 
[KE-436B, 436C] 
While pressing the TEST switch (3), press the R/W switch (4). 
4. If the input voltage is normal, the input voltage conditions will be shown in the display window (5) as indicated 
in the table above. 
Specifications Display 
Notes 
200V [090 
110] 
220V [100 
120] 
230V [105 
125] 
“100” is displayed when the input voltage is 200 V. 
100V 
380V 
400V 
415V 
[100 - 120] 
“110” is displayed when the input voltage is 
100V (for 100-V specs.), 380V (for 380-V specs.), 
400V (for 400-V specs.) or 415V (for 415-V specs.). 
 
5. Press the TEST switch (3) again to return the display to the normal condition. 
KE-430B, 430C series 