5. ADJUSTMENT 
 
5-30. Adjustment of air pressure (Pneumatic specifications) 
2622Q
Increase pressure 
Increase pressure
2621Q
1.  Air pressure should be 0.5 Mpa. 
The air pressure can be adjusted by pulling up 
and turning the control knob (2) on the 
integrator (1). 
After adjustment is complete, push the control 
knob (2) downward to lock it. 
2.  Adjust the air pressure for the reversal cylinder 
to stay within such a range that the presser 
crank (4) rotates reversely when pressing the 
sewing material with the pressure plate (3). 
(Approx. 0.3 Mpa) 
For adjustment, pull up and, turn the control 
knob (6) on the air regulator (5). 
After adjustment is complete, push the control 
knob (6) downward to lock it. 
3.  If water stands in the bottle of the integrator (1), 
turn the drain cock (7) in the direction indicated 
by an arrow to drain the water. 
 
 
 
 
 
 
 
 
 
5-31. Adjustment of inner clamping device 
Adjustment of the positioning plates 
Loosen the screws (2), and adjust the position of 
the positioning plate R (3) so that the label (1) can 
be evenly laid out between the front and back 
seams (A). 
Next, loosen the screws (4), and adjust the position 
of the positioning plate L (5) so that the presser 
plate can be evenly laid out between the left and 
right seams (B). 
 
 
 
 
 
Adjustment of the presser crank horizontal 
position
 
Loosen the nut (3) and push in or pull out the 
adjusting bolt (4) so that the presser crank (2) can 
be horizontal when the reversal cylinder piston rod 
(1) is moved to the left extreme. 
 
2623Q
2624Q
KE-430B, 430C series
 
132