Справочник Пользователя для Maximatic SBID 6052i

Скачать
Страница из 5
SMART Board
TM
 SBID 6052i  
Interactive Display Troubleshooting Guide
SMART Technologies
May 2010
Introduction
This document helps you to identify and resolve different issues that customers might have with the SMART Board
TM
 SBID 
6052i interactive display.  
Initial Troubleshooting
Customers call in for a variety of product issues. If you can’t easily identify the cause of the issue, it is recommended that 
you first instruct the customers to check the LED status and diagnostic lights to see if there are any issues with the touch 
connection panel (SC11). If the LED status and diagnostic lights indicate that the touch connection panel (SC11) is functioning, 
instruct the customers to run the SMART Connection Wizard to see if there are any touch connection panel (SC11) 
recognition, camera (s), pencil, eraser, or calibration issues. In addition, you can remind the customers to ensure their finger or 
pencil is at a right (90º) angle to the interactive display.
The following section outlines how to troubleshoot the interactive display using the LED status and diagnostic lights and the 
SMART Connection Wizard, and a tip on how to position your finger or pencil on the interactive display.
1. 
Troubleshoot touch connection panel (SC11) issues using the LED status and diagnostic lights
There are two LED status and diagnostic lights located on the touch connection panel (SC11). These two lights indicate the 
condition of the touch connection panel (SC11). Refer to p. 38–39 of the SMART Board SBID 6052i Interactive Display
TM 
Installation and User’s Manual for solutions if there are issues with the touch connection panel (SC11).
Note: The touch connection panel (SC11) is located behind the top-centre section of the interactive display. If your interactive 
display is mounted on a wall, you might require a ladder and mirror to see the LED status and diagnostic lights.  
2. 
 Troubleshoot touch connection panel (SC11) recognition, camera, pencil, eraser, or calibration issues by 
running the SMART Connection Wizard
If the computer doesn’t recognize the touch connection panel (SC11), or if there are potential issues with the camera(s), 
pencil, eraser, or calibration, always run the SMART Connection Wizard first to see if it can identify and resolve any related 
issues. To run the SMART Connection Wizard’s troubleshooting procedures, refer to p. 39–41 of the SMART Board SBID 6052i 
Interactive Display Installation and User’s Manual.
3. 
Position your finger or pencil at a right (90°) angle to the interactive display
For best results, keep your finger or pen at a right (90°) angle to the interactive display. Do not allow your wrist, clothing 
or other fingers to get too close to the display. This may trigger an inaccurate touch point. When you draw with your index 
finger, keep your other fingers curled up as if you were holding a coin in the palm of your hand. When you draw with a pen, 
hold your pen so that you fingers are away from the pen nib.