EXCESSIVE AIR PRESSURE 
STATIC SPARK
HAZARDOUS MATERIALS
HAZARDOUS PRESSURE
WARNING
 EXCESSIVE AIR PRESSURE. Can cause per- 
sonal injury, pump damage or property damage.
Do not exceed the maximum inlet air pressure as 
stated on the pump model plate.
Be sure material hoses and other components are able 
to withstand fluid pressures developed by this pump. 
Check all hoses for damage or wear. Be certain dispens-
ing device is clean and in proper working condition.
WARNING
 STATIC SPARK. Can cause explosion resulting in 
severe injury or death. Ground pump and pumping system. 
Sparks can ignite flammable material and vapors.  
The pumping system and object being sprayed must be 
grounded when it is pumping, flushing, recirculating or 
spraying flammable materials such as paints, solvents, 
lacquers, etc. or used in a location where surrounding 
atmosphere is conducive to spontaneous combustion. 
Ground the dispensing valve or device, containers, hos-
es and any object to which material is being pumped.
Secure pump, connections and all contact points to 
avoid vibration and generation of contact or static spark.
Consult local building codes and electrical codes for 
specific grounding requirements.
After grounding, periodically verify continuity of 
electrical path to ground. Test with an ohmmeter 
from each component (e.g., hoses, pump, clamps, con-
tainer, spray gun, etc.) to ground to insure continuity. 
Ohmmeter should show 0.1 ohms or less.
Submerse the outlet hose end, dispensing valve or 
device in the material being dispensed if possible. 
(Avoid free streaming of material being dispensed.)
Use hoses incorporating a static wire.
Use proper ventilation.
Keep inflammables away from heat, open flames and 
sparks.
Keep containers closed when not in use.
WARNING
 Pump exhaust may contain contaminants. 
Can cause severe injury. Pipe exhaust away from work 
area and personnel.
In the event of a diaphragm rupture, material can be 
forced out of the air exhaust muffler.
Pipe the exhaust to a safe remote location when 
pumping hazardous or inflammable materials.
Use a grounded 3/8” minimum i.d. hose between the 
pump and the muffler.
WARNING
 HAZARDOUS PRESSURE. Can result in 
serious injury or property damage. Do not service 
or clean pump, hoses or dispensing valve while the 
system is pressurized.
Disconnect air supply line and relieve pressure from 
the system by opening dispensing valve or device and 
/ or carefully and slowly loosening and removing out-
let hose or piping from pump.
WARNING
 HAZARDOUS MATERIALS. Can cause serious 
injury or property damage. Do not attempt to return 
a pump to the factory or service center that contains 
hazardous material. Safe handling practices must comply 
with local and national laws and safety code requirements.
Obtain Material Safety Data Sheets on all materials 
from the supplier for proper handling instructions.
WARNING
 EXPLOSION HAZARD. Models contain-
ing aluminum wetted parts cannot be used with III.-
Trichloroethane, Methylene Chloride or other Halo-
genated Hydrocarbon solvents which may react and 
explode.
Check pump motor section, fluid caps, manifolds and 
all wetted parts to assure compatibility before using 
with solvents of this type.
WARNING
 MISAPPLICATION HAZARD. Do not use 
models containing aluminum wetted parts with food 
products for human consumption. Plated parts can 
contain trace amounts of lead.
CAUTION
 Verify the chemical compatibility of the 
pump wetted parts and the substance being pumped, 
flushed or recirculated. Chemical compatibility may 
change with temperature and concentration of the 
chemical(s) within the substances being pumped, 
flushed or circulated. For specific fluid compatibility, 
consult the chemical manufacturer.
CAUTION
  Maximum  temperatures  are  based 
on mechanical stress only. Certain chemicals will 
significantly  reduce  maximum  safe  operating 
temperature. Consult the chemical manufacturer for 
chemical compatibility and temperature limits. Refer 
to PUMP DATA on page 1 of this manual.
CAUTION
 Be certain all operators of this equipment 
have  been  trained  for  safe  working  practices, 
understand it’s limitations, and wear safety goggles / 
equipment when required.
CAUTION
 Do not use the pump for the structural 
support of the piping system. Be certain the system 
components are properly supported to prevent stress 
on the pump parts.
Suction and discharge connections should be flexible 
connections (such as hose), not rigid piped, and should 
be compatible with the substance being pumped.
CAUTION
 Prevent unnecessary damage to the 
pump. Do not allow pump to operate when out of 
material for long periods of time.
Disconnect air line from pump when system sits idle 
for long periods of time.
CAUTION
 Use only genuine ARO replacement parts to 
assure compatible pressure rating and longest service life.
NOTICE
 RE-TORQUE ALL FASTENERS BEFORE 
OPERATION. Creep of housing and gasket materials 
may cause fasteners to loosen. Re-torque all fasteners 
to insure against fluid or air leakage.
WARNING
Hazards or unsafe practices which 
could result in severe personal injury, 
death or substantial property damage.
CAUTION
Hazards or unsafe practices which 
could result in minor personal injury, 
product or property damage.
NOTICE
Important installation, operation or
maintenance information.
OPERATING AND SAFETY PRECAUTIONS
READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.