1.  Setting the Detection Zone (Distance):
Remove the FAUCET COVER 
(1) by unthreading the 
LEVER SCREW 
(2) and pulling off the LEVER 
HANDLE 
(3). Unthread the FAUCET COVER SCREW 
(4) at the back of the FAUCET. Pull FAUCET COVER 
(1) up and off. Fig. 2.
2. Disconnect the BLACK POWER SUPPLY 
CONNECTOR 
(1) and reconnect. Fig. 3.
3. While the SENSOR CONTROL LED (2) is blinking 
slowly, place your hand 1 - 2 in. (25.4-50.8mm) in front 
of the sensor. 
Fig. 4.
4. When the LED stops blinking and stays "ON", move 
your hand to the desired position and hold in place until 
the LED begins to blink again. 
Fig. 4a.
5. Once the SENSOR CONTROL LED (2) begins to 
blink again, remove your hand from the detection zone. 
When the flashing stops, the detection distance is set.
6. Replace FAUCET COVER (1) and LEVER HANDLE 
(3). Install LEVER HANDLE SCREW (2), FAUCET 
COVER SCREW 
(4) and tighten. Fig. 2.
    HOW TO CHANGE SENSOR
RANGE; (Factory set at 6") Fig. 2
2
1
1
4
3
2
Fig. 4
Fig. 4a
UP TO 10"
(254mm)
BLINKING LED
REMOVE
REPLACE
2
BLINKING LED
2
1"-2"
(25.4mm-
50.8mm)