Справочник Пользователя для American Standard 2491

Скачать
Страница из 4
7 3 0110 2 - 10 0   Rev.  K
10
11
ADJUSTMENTS
  
a.  Adjust water level. Water level should
     be adjusted to level indicated on tank
     by adjusting float cup.
See Step 11 for water level adjustment 
method
b.  If bowl fails to siphon, an adjustment
     may be required with the lift chain. 
     Simply remove the bead chain from
     the retainment clip and take up slack
     on the chain, and reinsert on lift rod. 
     Make sure the chain is not too taught.
12
-   3   -
CARE AND CLEANING
When cleaning your toilet, wash it with mild, soapy water, rinse thoroughly with clear water and dry with a soft cloth. Avoid detergents, 
disinfectants, or cleaning products in aerosol cans. NEVER use abrasive scouring powders or abrasive pads on your toilet seat.  Some 
bathroom chemicals and cosmetics may damage the seat's finish.
WARNING:
 Do not use in-tank cleaners. Products containing chlorine (calcium hypochlorite) can seriously damage fittings in the 
tank. This damage can cause leakage and property damage.
American Standard shall not be responsible or liable for any tank fitting damage caused by the use of cleaners containing 
chlorine (calcium hypochlorite). 
13
• Make sure water supply is 
  off. Remove valve TOP by 
  lifting arm and rotating top 
  and arm 1/8 turn 
  counterclockwise, pressing 
  down slightly on cap.
IMPORTANT: Always clear 
sand and rust from system.
• While holding a container 
over the uncapped VALVE 
to prevent splashing, turn 
water supply on and off a 
few times. Leave water 
supply off.
• Replace TOP by engaging 
  lugs and rotating 1/8 turn   
  clockwise. MAKE CERTAIN 
  TIP IS TURNED TO THE 
  LOCKED POSITION. VALVE 
  MAY NOT TURN ON IF TOP 
  IS NOT FULLY TURNED TO 
  THE LOCKED POSITION.
For troubleshooting information please contact:
TROUBLESHOOTING
IF FILL VALVE SHUTS OFF BUT CONTINUES TO LEAK 
SLOWLY, 
repeat Step 13.
IF FILL VALVE TURNS OFF AND ON DURING PERIODS OF 
NON-USE, 
it is a signal you are wasting water because:
• The end of the refill tube is inserted into overflow pipe, below
   water level in tank. Attach refill tube to overflow pipe using "S"
   clip provided.
• The flush valve is leaking because it's worn, dirty or
   misaligned with tank ball or flapper (replace with a new flapper).
IF FILL VALVE WON'T TURN ON OR SHUT OFF or REFILL OF 
TANK WATER IS SLOW after valve has been in use for some 
time, 
Fluidmaster Model 242 Replacement Seal may be needed.
Go to our website at www.fluidmaster.com for more solutions 
to toilet problems.
©  2001 Fluidmaster, Inc.
®  Registered trademark of Fluidmaster, Inc.
Always use quality Fluidmaster repair parts when maintaining your Fluidmaster products. Fluidmaster shall 
not be responsible or liable for any damages caused by products used with Fluidmaster valves that were 
not manufactured by Fluidmaster, Inc.
30800 Rancho Viejo Road
San Juan Capistrano, CA 92675
(949) 728-2000  (800) 631-2011
www.fluidmaster.com
!
VALVE
BODY
ADJUSTABLE
HEIGHT
WATER LEVEL 
ADJUSTMENT 
ROD
Turn on water supply. 
Submerge the FLOAT CUP 
under the water for 30 seconds. 
Adjust the water to desired level 
by turning WATER LEVEL 
ADJUSTMENT ROD and 
moving FLOAT CUP up or 
down.
LIFT ARM
FIRST
TANK
LEVER
FLUSH
VALVE
TOP
ARM
NIPPLE
Diagram 1
PARTS FOR WATER
CONNECTION
(SEE STEP 9)
CONE WASHER
FLAPPER
THREADED
SHANK
SHANK
WASHER
COUPLING NUT
(HAND TIGHT ONLY)
FILL
VALVE
FLOAT
CUP
CRITICAL LEVEL
MARK ("C.L.")
MUST BE
1" ABOVE
OVERFLOW PIPE
REFILL
TUBE
LOCK NUT