Downloading Software
47
At the prompt, enter 
nvData
 
The nvdata menu options screen appears.
At the prompt, enter 
emergencyDownload
The following prompt appears:
Enter file server IP address {?} [<IP address>]:
Where 
<IP address>
 is the location of the server where the 
non-corrupted software image file resides. 
To modify the indicated IP address, enter an IP address, or to keep the 
existing IP address, press Enter.
The following prompt appears:
Enter image Name {?} [<image name>]:
Where 
<image name>
 is the stored image that you want to download.
Enter the <imagename> for the module to which you are connected. 
<imagename> is the image name with the .ALL extension for this 
module.
The following prompt appears:
Enter file type {?} [file type]:
Enter 
all_image
 for 
file type
.
Enter 
q
 and press Enter until you reach the top-level menu options screen. 
To close the menu options screen, enter 
disconnect
10 To update the Automatic Emergency Download fields in the EME
show module <slot>.1
 command display, reset the module using the 
following EME command:
CB9000> reset module <slot>.1
You must complete step 10 to ensure that the module is updated.