§4.0  INSTALLATION 
PLEASE READ CAREFULLY BEFORE BEGINNING INSTALLATION.  FAILURE TO FOLLOW 
THESE PROCEDURES CAN RESULT IN DAMAGE TO YOUR SYSTEM AND VOID YOUR 
WARRANTY. 
§4.1  LOCATION 
It is recommended that systems be located where they are protected from harsh environments 
such as rain, snow and extreme temperatures (both hot and cold).  MN-800 TF units can be 
located just about anywhere there is a water and electrical supply.  This can be on the floor, 
mounted on the wall with a shelf, or any other flat surface.  Keep in mind, however, that they 
should be out of normal traffic patterns and should be easily accessed for daily monitoring and 
service. 
§4.2  SYSTEM PLUMBING INSTALLATION GUIDE LINES 
A complete plumbing diagram of the system installation is shown in Figure 2.  Always abide by 
local plumbing codes when installing the system.  We recommend that a licensed plumbing 
contractor install this system.  When installation procedures conflict with your local plumbing 
codes, STOP and contact Nimbus.  This installation guide assumes the appropriate electrical 
outlet, 2 city water valves (1/2” FPT) and 1 valve (1/2” FPT) for distribution to the food service 
machines have been installed convenient to the system installation location.  All threaded fittings 
are to be installed with Teflon tape. 
 
IMPORTANT: FOR PLASTIC TUBING, USE ONLY SUPPLIED NYLON FERRULES AND 
BRASS TUBE INSERTS.  DO NOT USE BRASS FERRULES ON PLASTIC TUBING.   
 
§4.2.1 TANK PREPARATION AND INSTALLATION
Install the 1-¼” x ¾” bushing In the 1-¼” FPT fitting at the bottom of the tank then install the ¾” 
MPT x 5/8” compression elbow in the bushing.  Direct the 5/8” compression end toward the 
opening in the tank skirt.  Cut a piece of black 5/8” tubing to extend about 4” beyond the tank 
skirt.  Then install the tubing into the 5/8” compression fitting on the tank outlet.   
 
Follow the instructions included with the tank wall brace kit to secure the tank to the rear wall. 
Locate the restraint brackets about 15” and 30” above the floor.  Set the tank in place and 
rotate it so the bottom tank outlet is positioned as desired.  Tighten the bracket clamps securely 
around the tank. 
 
Remove the blue protective cap from the nut on top of the tank.  Install the 5/8” x 1-½” long stud 
in the nut.  Install the black plastic feet on the legs of the RO frame then lift and place the RO 
system on top of the tank with the threaded stud extending through the hole in the center of the 
RO frame base.  Install the flat washer and nut on the stud.  Rotate the RO so there is access 
to the 20” filters on the front of the unit.  Tighten the 5/8” nut to secure the RO to the tank. 
 
Install the ½” ball valve on the 5/8” tubing on the outlet of the tank. Use one straight and one 
elbow of ½” MPT x 5/8” compression fitting.  With these fittings the valve can be installed 
straight out from the tank or pointing vertically up the side of the tank as desired.  Connect a