Справочник Пользователя для StorageTek 6

Скачать
Страница из 718
Chapter 4. Utility Functions   203
1st ed., 6/30/04 - 312579601
 
LSM 
optionally specifies that only certain LSMs within the specified ACS are to be 
audited. 
(lsm-list) 
An lsm-list can be a single LSMid or a list of LSMids. An LSMid (lsm-id) is 
made up of the ACSid (hexadecimal 00-FF) and the LSM number (hexadecimal 
00-17) separated by a colon (:). An LSM range is not allowed. If a list is 
specified, the elements must be separated by blanks or commas, and the entire 
list enclosed in parentheses. 
PANel 
optionally specifies that only certain panels within an LSM are to be audited. 
(panel-list) 
panel-list may be a single panel or a list of panels. Panel ranges are not allowed. 
If a list is specified, the elements must be separated by blanks or commas, and 
the entire list enclosed in parentheses. 
Refer to the appropriate ACS hardware document for information about LSM 
outer and inner wall panel layouts. 
Note: If this parameter is specified, the LSM parameter may contain only one 
LSM number.
panel-list element is a one or two digit decimal number. 
• For 4410 and 9310 LSMs, valid panel entries are 0 through 11 (outer LSM 
wall panels) and 12 through 19 (inner wall panels). 
• For 9360 (WolfCreek) LSMs, valid panel entries are 0 through 4. 
• For 9740 (TimberWolf) LSMs, valid panel entries are 0 through 3. 
• For SL8500 (StreamLine) libraries, valid panel entries are:
- base library — 2-10
- with one expansion panel — 2-18 (expansion panel is 8-15)
- with two expansion panels — 2-26 (expansion panels are 8-23)
- with three expansion panels — 2-34 (expansion panels are 8-31).
Audit