Troubleshooting
41
Rev A
9. Intermittent or 
irregular 
regenerant draw.
a. Low water pressure.
b. Defective injector.
a. Set pump to maintain 20 psi at conditioner.
b. Replace injector. (Contact dealer.)
10. No conditioned 
water after 
regeneration.
a. No regenerant in regenerant 
tank.
b. Injector plugged.
c. Air check valve closes 
prematurely.
a. Add regenerant to regenerant tank.
b. Clean injector and screen.
c. Put control momentarily into brine/slow 
rinse. Replace or repair air check if needed.  
(Contact dealer.)
11. Backwashes or 
purges at 
excessively low 
or high rate.
a. Incorrect drain controller used.
b. Foreign matter affecting valve 
operation.
a. Replace with correct size controller. (Contact 
dealer.)
b. Remove drain controller and clean ball and 
seat.
12. No water flow 
display when 
water is flowing.
a. Bypass valve in bypass.
b. Meter probe disconnected or not 
fully connected to meter 
housing.
c. Restricted meter turbine rotation 
due to foreign material in meter.
a. Shift bypass valve to not-in-bypass position.
b. Fully insert probe into meter housing.
c. Remove meter housing, free up turbine and 
flush with clean water. Turbine should spin 
freely. If not, replace meter. (Contact dealer.)
13. Run out of 
conditioned 
water between 
regenerations.
a. Improper regeneration.
b. Incorrect regenerant setting.
c. Incorrect hardness or capacity 
settings.
d. Water hardness has increased.
e. Restricted meter turbine rotation 
due to foreign material in meter.
a. Repeat regeneration, making certain that 
correct regenerant dosage is used.
b. Set P6 to proper level. See salt setting chart. 
c. Set to correct values. See Programming 
section.
d. Set hardness to new value. See 
Programming section.
e. Remove meter housing, free up turbine and 
flush with clean water. Turbine should spin 
freely; if not, replace meter. (Contact dealer.)
14. Regenerant tank 
overflow.
a. Regenerant valve disc 1 being 
held open by foreign matter.
b. Valve disc 2 not closed during 
regenerant draw causing brine 
refill.
c. Air leak in regenerant line to air 
check.
d. Improper drain control for 
injector.
e. Drain control clogged with resin 
or other debris.
a. Manually operate valve stem to flush away 
obstruction.
b. Flush out foreign matter holding disc open 
by manually operating valve stem.
c. Check all connections in regenerant line for 
leaks. Refer to instructions.
d. Too small of a drain control with a larger 
injector will reduce draw rates.
e. Clean drain control.