Water/Spray Tanks
UGE014/0999
3-6
I
NSTALLATION
The standard WT.ST tanks are designed for use with city,
tower or chilled water supplies. You may choose to treat the
water to prevent algae build-up.
Connect the main water supply 
to the 1
1
/
2
-inch
NPT fitting on the tank.
Connect the compressed air supply 
to the fitting
on the tank air wipe compartment.
C
ONNECTING
THE
W
ATER AND
A
IR
S
UPPLIES
WARNING:
Do not use deionized water, brine
or other corrosive water mixtures for the main water
supply unless your tank has been specially designed
for such mixtures. Consult a water treatment special-
ist for the best way to prevent algae build-up without
damaging the equipment.
1
2
You can connect a chiller to the tank’s optional heat exchang-
er to remove heat from the extrudate more efficiently.
Typically, the tank comes with the 3/4 inch lines of the stan-
dard tube and shell heater plumbed to the tank’s water mani-
fold. The 1
1
/
2
inch inlet and outlet of the heat exchanger can
be used for the chiller.
For maximum water flow:
Connect the chiller “To Process” and “From Process” lines to
the largest NPT fittings in the shell of the heat exchanger.
For maximum cooling efficiency:
Connect the chiller “To Process” and “From Process” lines to
the smallest NPT tube ends of the heat exchanger.
TIP: If you have a water
supply with high mineral
content, connect the chiller
to the tube ends of the
heat exchanger.
C
ONNECTING A
C
HILLER
From chiller
To chiller
To water manifold
From water
pump
From chiller
To chiller
To water manifold
From water pump